Increased diffusion sensitivity with hyperechos

被引:5
作者
Frank, LR
Wong, EC
Liu, TT
Buxton, RB
机构
[1] Univ Calif San Diego, Ctr Funct MR1, La Jolla, CA 92093 USA
[2] San Diego VA Healthcare Syst, San Diego, CA USA
关键词
diffusion; hyperechoes; high angular resolution diffusion; diffusion anisotropy;
D O I
10.1002/mrm.10457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
It is shown that the introduction of a 180degrees refocusing pulse into a standard diffusion weighted stimulated echo sequence is equivalent to the simplest hyperecho sequence with identical diffusion weighting but equal or greater signal-to-noise (SNR) and thus equal or greater diffusion contrast. For high b-value imaging, the hyperecho sequence thus possesses the high diffusion contrast in the presence of small T-1/T-2 ratios characteristic of stimulated echo sequences but with less than the 50% loss in SNR that is associated with the stimulated echo. For low b-value imaging, the hyperecho signal converges to that of the standard spin echo. The advantages of the two-pulse diffusion weighted hyperecho sequence are demonstrated theoretically. Experimental results are shown in the application to high angular resolution diffusion encoding (HARD) in normal human brain. Published 2003 Wiley-Liss, Inc.
引用
收藏
页码:1098 / 1105
页数:8
相关论文
共 23 条
[1]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[2]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[3]   Characterization of anisotropy in high angular resolution diffusion-weighted MRI [J].
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1083-1099
[4]   Anisotropy in high angular resolution diffusion-weighted MRI [J].
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :935-939
[5]  
FRANK LR, 2002, P 10 ANN M ISMRM HON, P434
[6]  
Glover GH, 1999, MAGNET RESON MED, V42, P412, DOI 10.1002/(SICI)1522-2594(199908)42:2<412::AID-MRM25>3.0.CO
[7]  
2-U
[8]   DETECTION OF SEA-WATER MOTION BY NUCLEAR PRECESSION [J].
HAHN, EL .
JOURNAL OF GEOPHYSICAL RESEARCH, 1960, 65 (02) :776-777
[9]   Hyperechoes [J].
Hennig, J ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :6-12
[10]   MULTIECHO IMAGING SEQUENCES WITH LOW REFOCUSING FLIP ANGLES [J].
HENNIG, J .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :397-407