Accurate recognition and effective treatment of ventricular fibrillation by automated external defibrillators in adolescents

被引:57
作者
Atkins, DL
Hartley, LL
York, DK
机构
[1] Univ Iowa, Dept Pediat, Div Pediat Cardiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Emergency Med Serv, Learning Resources Ctr, Iowa City, IA 52242 USA
关键词
automatic external defibrillator; ventricular fibrillation; adolescent; child; cardiac arrest; defibrillation; resuscitation;
D O I
10.1542/peds.101.3.393
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives. To evaluate the accuracy and efficacy of automated external defibrillators (AEDs) in patients <16 years old. Background. AEDs are standard therapy in out-of-hospital resuscitation of adults and have led to higher success rates. Their use in children and adolescents has never been evaluated, despite recommendations from the American Heart Association that they be used in children >8 years of age. Methods. This was a retrospective cohort study of children <16 years old who underwent out-of-hospital cardiac resuscitation and on whom an AED was used during the resuscitation. The setting was rural and urban prehospital emergency medical systems. Patients were identified by review of a database of cardiac arrests maintained by a large surveillance program of these services. Results. AEDs were used to assess cardiac rhythm in 18 patients with a mean age of 12.1 +/- 3.7 years. The cardiac rhythms were analyzed 67 times and included ventricular fibrillation (25), asystole/pulseless electrical activity (32), sinus bradycardia (6), and sinus tachycardia (4). The AEDs recognized all nonshockable rhythms accurately and advised no shock. Ventricular fibrillation was recognized accurately in 22 (88%) of 25 episodes and advised or administered a shock 22 times. Sensitivity and specificity for accurate rhythm analysis were 88% and 100%, respectively. One patient with a nonshockable rhythm survived, whereas 3 of 9 patients with ventricular fibrillation survived. Conclusions. These data furnish evidence that AEDs provide accurate rhythm detection and shock delivery to children and young adolescents. AED use is potentially as effective for children as it is for adults.
引用
收藏
页码:393 / 397
页数:5
相关论文
共 32 条
  • [1] ATKINS DL, 1994, PEDIATRICS, V94, P90
  • [2] THERAPEUTIC INDEXES FOR TRANSCHEST DEFIBRILLATOR SHOCKS - EFFECTIVE, DAMAGING, AND LETHAL ELECTRICAL DOSES
    BABBS, CF
    TACKER, WA
    VANVLEET, JF
    BOURLAND, JD
    GEDDES, LA
    [J]. AMERICAN HEART JOURNAL, 1980, 99 (06) : 734 - 738
  • [3] A STUDY OF OUT-OF-HOSPITAL CARDIAC ARRESTS IN NORTHEASTERN MINNESOTA
    BACHMAN, JW
    MCDONALD, GS
    OBRIEN, PC
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1986, 256 (04): : 477 - 483
  • [4] OUTCOME OF CPR IN A LARGE METROPOLITAN-AREA - WHERE ARE THE SURVIVORS
    BECKER, LB
    OSTRANDER, MP
    BARRETT, J
    KONDOS, GT
    [J]. ANNALS OF EMERGENCY MEDICINE, 1991, 20 (04) : 355 - 361
  • [5] CHAMEIDES L, 1994, ADV PEDIAT LIFE SUPP
  • [6] AUTOMATIC EXTERNAL DEFIBRILLATORS USED BY EMERGENCY MEDICAL TECHNICIANS - A CONTROLLED CLINICAL-TRIAL
    CUMMINS, RO
    EISENBERG, MS
    LITWIN, PE
    GRAVES, JR
    HEARNE, TR
    HALLSTROM, AP
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 257 (12): : 1605 - 1610
  • [7] CUMMINS RO, 1984, LANCET, V2, P318
  • [8] A NEW RHYTHM LIBRARY FOR TESTING AUTOMATIC EXTERNAL DEFIBRILLATORS - PERFORMANCE OF 3 DEVICES
    CUMMINS, RO
    STULTS, KR
    HAGGAR, B
    KERBER, RE
    SCHAEFFER, S
    BROWN, DD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (03) : 597 - 602
  • [9] DIACK AW, 1979, MED INSTRUM, V13, P78
  • [10] EISENBERG M, 1983, ANN EMERG MED, V12, P672, DOI 10.1016/S0196-0644(83)80413-2