Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications

被引:26
作者
Aslam [1 ]
Prestwich, WV
McNeill, FE
Waker, AJ
机构
[1] McMaster Univ, Med Phys & Appl Radiat Sci Unit, Hamilton, ON L8S 4K1, Canada
[2] AECL Res, Chalk River Labs, Chalk River, ON K0J 1J0, Canada
关键词
D O I
10.1093/oxfordjournals.rpd.a006148
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
The use of a tissue equivalent proportional counter (TEPC) filled with propane based tissue equivalent gas simulating a 2 put diameter tissue sphere has been investigated to estimate the radiation quality factor of the neutron fields used in in vivo neutron activation measurements at the McMaster University 3 MV Van de Graaff accelerator. The counter response to estimate the effective quality factor based on the definitions of Q(L) provided in ICRP 26 and 60 as a function of neutron energy has been examined experimentally using monoenergetic and continuous neutron spectra in the energy range of 35 to 600 keV. In agreement with other studies, the counter failed to provide a flat R-Q response and showed a sharp drop below 200 keV neutron energy. Development of an algorithm to evaluate the quality factors using measured dose-mean lineal energy, (y) over bar (D), and comparison of the algorithm with other reported algorithms and analytical methods developed for the improvement in TEPC dose equivalent response has been reported.
引用
收藏
页码:311 / 322
页数:12
相关论文
共 65 条
[1]
ALBERTS WG, 1989, RADIAT PROT DOSIM, V29, P47
[2]
A DESIGN STUDY FOR AN ACCELERATOR-BASED EPITHERMAL NEUTRON BEAM FOR BNCT [J].
ALLEN, DA ;
BEYNON, TD .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :807-821
[3]
[Anonymous], 1986, 40 ICRU
[4]
Arnold ML, 1999, NEUROTOXICOLOGY, V20, P407
[5]
An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones [J].
Arnold, ML ;
McNeill, FE ;
Stronach, IM ;
Pejovic-Milic, A ;
Chettle, DR ;
Waker, A .
MEDICAL PHYSICS, 2002, 29 (11) :2718-2724
[6]
System design for in vivo neutron activation analysis measurements of manganese in the human brain: based on Monte Carlo modeling [J].
Arnold, ML ;
McNeill, FE ;
Prestwich, WV ;
Chettle, DR .
APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) :651-656
[7]
ARNOLD ML, 2000, THESIS MCMASTER U HA
[8]
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[9]
DOSE EQUIVALENT METER DESIGNS BASED ON TISSUE EQUIVALENT PROPORTIONAL COUNTERS [J].
BAUM, JW ;
KUEHNER, AV ;
CHASE, RL .
HEALTH PHYSICS, 1970, 19 (06) :813-+
[10]
Accelerator-based neutron source for the neutron-capture and fast neutron therapy at hospital [J].
Bayanov, BF ;
Belov, VP ;
Bender, ED ;
Bokhovko, MV ;
Dimov, GI ;
Kononov, VN ;
Kononov, OE ;
Kuksanov, NK ;
Palchikov, VE ;
Pivovarov, VA ;
Salimov, RA ;
Silvestrov, GI ;
Skrinsky, AN ;
Soloviov, NA ;
Taskaev, SY .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 413 (2-3) :397-426