Optimisation of strain rate imaging for application to stress echocardiography

被引:12
作者
Hanekom, L [1 ]
Lundberg, V [1 ]
Leano, R [1 ]
Marwick, TH [1 ]
机构
[1] Univ Queensland, Princess Alexandra Hosp, Dept Med, Brisbane, Qld 4102, Australia
基金
英国医学研究理事会;
关键词
dobutamine stress echo; strain rate; tissue Doppler; ischaemia;
D O I
10.1016/j.ultrasmedbio.2004.08.026
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We sought to improve the feasibility of strain rate imaging (SRI) during dobutamine stress echocardiography (DSE) in 56 subjects at low risk of coronary disease. The impact of several SRI changes during acquisition were studied, including: (1) changing from fundamental to harmonic imaging; (2) parallel beam-forming; (3) alteration of spatial resolution and (4) narrow sector acquisition. We assessed SR signal quality, a quantitative measure of signal noise and measurements of SRI. Of 1462 segments evaluated, 6% were uninterpretable at rest and 8% at peak stress. Signal quality was optimised by increasing temporal (p = 0.01) and spatial resolution (p<0.0001 vs. baseline imaging) at rest and peak. Increasing spatial resolution also minimised signal noise (p<0.0001). Inter-observer variability of time to peak SR and peak SR were less with high temporal and spatial resolution. SRI quality can be improved with harmonic imaging and higher temporal resolution but optimisation of spatial resolution is critical. (C) 2004 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1451 / 1460
页数:10
相关论文
共 20 条
[1]  
Castro PL, 2000, BIOMED SCI INSTRUM, V395, P197
[2]  
D'hooge J, 2000, Eur J Echocardiogr, V1, P154, DOI 10.1053/euje.2000.0031
[3]   Quantitative assessment of intrinsic regional myocardial deformation by Doppler strain rate echocardiography in humans - Validation against three-dimensional tagged magnetic resonance imaging [J].
Edvardsen, T ;
Gerber, BL ;
Garot, J ;
Bluemke, DA ;
Lima, JAC ;
Smiseth, OA .
CIRCULATION, 2002, 106 (01) :50-56
[4]   Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography [J].
Geleijnse, ML ;
Fioretti, PM ;
Roelandt, JRTC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :595-606
[5]   Accuracy of contrast-enhanced magnetic resonance imaging in predicting improvement of regional myocardial function in patients after acute myocardial infarction [J].
Gerber, BL ;
Garot, J ;
Bluemke, DA ;
Wu, KC ;
Lima, JAC .
CIRCULATION, 2002, 106 (09) :1083-1089
[6]   Real-time strain rate imaging of the left ventricle by ultrasound [J].
Heimdal, A ;
Stoylen, A ;
Torp, H ;
Skjaerpe, T .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (11) :1013-1019
[7]  
Heimdal A, 1998, ULTRASON, P1361, DOI 10.1109/ULTSYM.1998.765148
[8]   Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms [J].
Hoffmann, R ;
Lethen, H ;
Marwick, T ;
Arnese, M ;
Fioretti, P ;
Pingitore, A ;
Picano, E ;
Buck, T ;
Erbel, R ;
Flachskampf, FA ;
Hanrath, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (02) :330-336
[9]  
Kowalski M, 2003, Eur J Echocardiogr, V4, P81, DOI 10.1053/euje.2002.0174
[10]   Can natural strain and strain rate quantify regional myocardial deformation? A study in healthy subjects [J].
Kowalski, M ;
Kukulski, T ;
Jamal, F ;
D'Hooge, J ;
Weidemann, F ;
Rademakers, F ;
Bijnens, B ;
Hatle, L ;
Sutherland, GR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (08) :1087-1097