Improvement in modeling of heat transfer in vertical ground heat exchangers

被引:111
作者
Diao, NR [1 ]
Zeng, HY
Fang, ZH
机构
[1] Tsing Hua Univ, Dept Engn Mech, Beijing 100084, Peoples R China
[2] Shandong Inst Architecture & Engn, Ground Source Heat Pump Res Ctr, Jinan, Peoples R China
来源
HVAC&R RESEARCH | 2004年 / 10卷 / 04期
关键词
D O I
10.1080/10789669.2004.10391114
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer model of vertical ground heat exchangers for ground-source heat pump systems is discussed. An explicit solution of a finite line-source model has been derived to better describe temperature response of boreholes for long time steps, which can be easily incorporated into computer programs for thermal analysis of ground heat exchangers. A quasi-three-dimensional model is also presented for heat transfer inside the borehole, accounting for thermal interference between the U-tube legs. On this basis a concise expression is obtained for the thermal resistance inside the borehole. These models have a more solid theoretical basis, would help to improve design procedures recommended by available literature, and are yet suitable for engineering applications.
引用
收藏
页码:459 / 470
页数:12
相关论文
共 17 条
[1]  
[Anonymous], 1999, ASHRAE Trans
[2]  
[Anonymous], 1985, DESIGN DATA MANUAL C
[3]  
*CAN RES INC, 1995, COMM I GROUND SOURC
[4]  
Carslaw H. S., 1959, CONDUCTION HEAT SOLI
[5]  
Chiasson A., 2000, ASHRAE Trans, V106, P380
[6]  
Diao NR, 2003, J SHANDONG I ARCHITE, V18, P1
[7]  
DIAO NR, 2002, HEAT TRANSFER 2002, P18
[8]  
Eskilson P., 1987, THERMAL ANAL HEAT EX
[9]  
Fang Z.H., 2002, P IEA 7 HEAT PUMP C, P356
[10]  
Fang Zhaohong, 2002, Tsinghua Science and Technology, V7, P194