Specific determination of PAH and its N-acetyl metabolite by HPLC increases the accuracy and precision of PAH clearance measurements

被引:2
作者
Decosterd, LA [1 ]
Bélaz, N [1 ]
Appenzeller, M [1 ]
Maghraoui, A [1 ]
Rousso, P [1 ]
Buclin, T [1 ]
Biollaz, J [1 ]
机构
[1] CHU Vaudois, Dept Med, Div Clin Pharmacol, CH-111 Lausanne, Switzerland
关键词
clearance; colorimetry; HPLC; N-acetyl-p-amino-hippuric acid; P-amino-hippuric acid; renal blood flow;
D O I
10.3109/08860229809045116
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
PAH (N-(4-aminobenzoyl)-glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction. Although straightforward, the measurements must be corrected for the nonspecific residual response observed in blank plasma. We have therefore developed an HPLC method for the specific determination of PAH and its metabolite NAc-PAH using a gradient elution ion-pair reverse-phase chromatography with UV detection. The Nacetyltransferase (NAT-1 or NAT-2 dependent) activity does not seem clinically relevant nor does if affect notably PAH clearances, although NAc-PAH represents 10.2 +/- 2.7% of the PAH excreted unchanged in 12 healthy subjects The performance of the HPLC technique has been compared with the colorimetric method using urine and plasma samples collected fr om 12 healthy volunteers following a priming dose of PAH followed by a constant rate infusion. Good correlations (r = 0.94 and 0.97 for plasma and urine respectively) are found between the results obtained with both techniques; However, the colorimetric method gives higher concentrations of PAH in urine while the concentrations in plasma are lower than those determined by HPLC. Hence, both renal (CLR = UxV/P) and systemic (CLS = R-inf/C-ss) clearances are systematically higher (35.1% resp. 17.8%) with the colorimetric method. The fraction of FAH excreted by the kidney CLR/CLS calculated front HPLC data (n = 143) is, as expected, always < 1 (mean = 0.73 +/- 0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87 +/- 0.13 implying unphysio-logical values (> 1) in some cases. In conclusion HPLC not only enables the simultaneous quantitation ofPAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 7 条
[1]  
DECOSTERD LA, UNPUB J CHROMATOG BI
[2]   THE CLEARANCE OF INULIN AND SODIUM PARA-AMINOHIPPURATE IN THE RAT [J].
FRIEDMAN, SM ;
POLLEY, JR ;
FRIEDMAN, CL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1947, 150 (02) :340-352
[3]   QUANTITATION OF PARA-AMINOHIPPURIC ACID IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND DUAL-WAVELENGTH ULTRAVIOLET DETECTION [J].
JENNY, PD ;
WEBER, A ;
SMITH, AL .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 490 (01) :213-218
[4]  
KIGUCHI M, 1987, Journal of Toxicological Sciences, V12, P301
[5]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268
[6]  
MCAUSLANE JAN, 1987, BRIT J CLIN PHARMACO, V24, pP277
[7]  
PRESCOTT LF, 1993, BRIT J CLIN PHARMACO, V35, P20