Chemiluminescence from the oxidation of urea and ammonia with hypobromite and N-bromosuccinimide

被引:15
作者
Francis, PS [1 ]
Barnett, NW [1 ]
Lewis, SW [1 ]
Lim, KF [1 ]
机构
[1] Deakin Univ, Ctr Chiral & Mol Technol, Sch Biol & Chem Sci, Geelong, Vic 3217, Australia
关键词
N-bromosuccinimide; chemiluminescence; hypobromite;
D O I
10.1016/j.talanta.2004.02.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The spectral distribution for the chemiluminescent oxidation of ammonia with hypobromite is significantly different to that for the oxidation of ammonia with N-bromosuccinimide. Therefore, in contrast to the assumptions of several authors, the action of N-bromosuccinimide is not solely derived from the in situ formation of hypobromite. Neither the oxidation of urea with hypobromite nor the oxidation of urea with N-bromosuccinimide involves an initial hydrolysis of urea to ammonia in the alkaline solution. However, these two reactions lead to a common emitter. The addition of xanthene dyes, such as dichlorofluorescein, enhance the chemiluminescence intensity by energy transfer to the efficient fluorophore, but reaction between the sensitiser and hypobromite can result in a significant increase in the background signal. A list of potential interferences has been compiled; particular attention was paid to guanidino compounds, as the chemiluminescence accompanying the oxidation of this functional group has not been previously discussed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 45 条
[1]  
Abdullin IF, 1997, J ANAL CHEM+, V52, P264
[2]  
CHAKRABARTTY SK, 1978, ORG CHEM NY, V5, P343
[3]  
CHEN GN, 1994, ANAL CHIM ACTA, V292, P159
[4]  
Colour Index, 1971, COL IND, V4, P4425
[5]   Selective determination of amino acids using flow injection analysis coupled with chemiluminescence detection [J].
Costin, JW ;
Francis, PS ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 2003, 480 (01) :67-77
[6]   PICOSECOND FLUORESCENCE STUDIES OF XANTHENE DYES [J].
FLEMING, GR ;
KNIGHT, AWE ;
MORRIS, JM ;
MORRISON, RJS ;
ROBINSON, GW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1977, 99 (13) :4306-4311
[7]  
Garcia-Campana A. M., 2001, CHEMILUMINESCENCE AN
[8]   CONTINUOUS-FLOW CHEMILUMINOMETRIC DETERMINATION OF AMILORIDE AND STREPTOMYCIN BY OXIDATION WITH N-BROMOSUCCINIMIDE [J].
HALVATZIS, SA ;
MIHALATOS, AM ;
PALILIS, LP ;
CALOKERINOS, AC .
ANALYTICA CHIMICA ACTA, 1994, 290 (1-2) :172-178
[9]   CONTINUOUS-FLOW CHEMILUMINESCENCE DETERMINATION OF ISONIAZID BY OXIDATION WITH N-BROMOSUCCINIMIDE [J].
HALVATZIS, SA ;
TIMOTHEOUPOTAMIA, MM ;
CALOKERINOS, AC .
ANALYST, 1990, 115 (09) :1229-1234
[10]   CONTINUOUS-FLOW CHEMILUMINOMETRIC DETERMINATION OF TETRACYCLINES IN PHARMACEUTICAL PREPARATIONS AND HONEY BY OXIDATION WITH N-BROMOSUCCINIMIDE [J].
HALVATZIS, SA ;
TIMOTHEOUPOTAMIA, MM ;
CALOKERINOS, AC .
ANALYST, 1993, 118 (06) :633-637