Single versus double column fixation in transverse fractures of the acetabulum: A randomised controlled trial

被引:12
作者
Fahmy, Mahmoud [1 ]
Karim, Mahmoud Abdel [1 ]
Khaled, Sherif A. [1 ]
Abdelazeem, Ahmed Hazem [1 ]
Elnahal, Walid A. [1 ]
Elnahal, Ashraf [1 ]
机构
[1] Cairo Univ Hosp, Cairo, Egypt
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2018年 / 49卷 / 07期
关键词
Acetabular; Transverse; Fracture; Column; Fixation; OPERATIVE TREATMENT; REDUCTION;
D O I
10.1016/j.injury.2018.05.024
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Introduction: Biomechanical studies have compared fixation methods in transverse acetabular fractures, yet there is not enough clinical data to suggest an optimal fixation method. The aim of this randomized controlled trail was to compare fracture stability in posterior plating alone versus posterior plating and anterior column lag-screw fixation in treatment of transverse and transverse with posterior wall acetabular fractures. Methods: Thirty patients were randomized to one of two groups, either posterior fixation alone (single column group), or posterior plating and anterior fixation with percutaneous anterior column screw (double column group). Patients were followed up with serial radiographic assessments documenting any loss of reduction, utilizing Matta's radiological criteria, measuring the roof arc angles and by measuring any change in the femoral head offset. Results: Fifteen patients were randomized to each group. Mean patient age was 31 years, mean follow up period was 19 months (range 12-24). There was no significant differences between the two groups with regards the quality of post-operative reduction, blood loss, hospital stay and functional score using the modified Merle D'Aubinge and Postel score. The operative time was significantly longer in the double column fixation group (130 min versus 104 min). There was no loss of reduction observed in either of the two groups. Conclusion: Single poster column fixation in transverse and transverse posterior wall fractures showed similar result to double column fixation, in terms of fractures stability in the follow up period, quality of reduction and early functional outcome. (C) 2018 Published by Elsevier Ltd.
引用
收藏
页码:1291 / 1296
页数:6
相关论文
共 15 条
[1]
Outcomes of acetabular fracture fixation with ten years' follow-up [J].
Briffa, N. ;
Pearce, R. ;
Hill, A. M. ;
Bircher, M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (02) :229-236
[2]
Chang JK, 2001, CLIN ORTHOP RELAT R, P433
[3]
Gänsslen A, 2013, ACTA CHIR ORTHOP TR, V80, P27
[4]
Giannoudis PV, 2005, BONE JOINT J, V87
[5]
Giordano V, 2009, INT J MED SCI, V6, P192
[6]
Letournel E, 1993, FRACTURES ACETABULUM
[7]
Li Xi-gong, 2010, Orthop Surg, V2, P7, DOI 10.1111/j.1757-7861.2009.00056.x
[8]
Outcome of surgery for reconstruction of fractures of the acetabulum - The time dependent effect of delay [J].
Madhu, R. ;
Kotnis, R. ;
Al-Mousawi, A. ;
Barlow, N. ;
Deo, S. ;
Worlock, P. ;
Willett, K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (09) :1197-1203
[9]
Surgical Dislocation Technique for the Treatment of Acetabular Fractures [J].
Masse, Alessandro ;
Aprato, Alessandro ;
Rollero, Luca ;
Bersano, Andrea ;
Ganz, Reinhold .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (12) :4056-4064
[10]
MATTA JM, 1986, CLIN ORTHOP RELAT R, P230