Simple flow-injection system for the simultaneous determination of nitrite and nitrate in water samples

被引:85
作者
Burakham, R
Oshima, M
Grudpan, K
Motomizu, S
机构
[1] Okayama Univ, Fac Sci, Dept Chem, Okayama 7008530, Japan
[2] Chiang Mai Univ, Fac Sci, Dept Chem, Chiang Mai 50200, Thailand
关键词
flow-injection analysis; phloroglucinol; nitrite; nitrate; simultaneous determination;
D O I
10.1016/j.talanta.2004.03.059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel spectrophotometric reaction system was developed for the determination of nitrite as well as nitrate in water samples, and was applied to a flow-injection analysis (FIA). The spectrophotometric flow-injection system coupled with a copperised cadmium reductor column was proposed. The detection was based on the nitrosation reaction between nitrite ion and phloroglucinol (1,3,5-trihydroxybenzene), a commercially available phenolic compound. Sample injected into a carrier stream was split into two streams at the Y-shaped connector. One of the streams merged directly and reacted with the reagent stream: nitrite ion in the samples was detected. The other stream was passed through the copperised cadmium reductor column, where the reduction of nitrate to nitrite occurred, and the sample zone was then mixed with the reagent stream and passed through the detector: the sum of nitrate and nitrite was detected. The optimised conditions allow a linear calibration range of 0.03-0.30 mug NO2--N ml(-1) and 0.10-1.00 mug NO3--N ml(-1). The detection limits for nitrite and nitrate, defined as three times the standard deviation of measured blanks are 2.9 ng NO2--N ml(-1) and 2.3 ng NO3--N ml(-1), respectively. Up to 20 samples can be analyzed per hour with a relative standard deviation of less than 1.5%. The proposed method could be applied successfully to the simultaneous determination of nitrite and nitrate in water samples. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1259 / 1265
页数:7
相关论文
共 26 条
[1]   DETERMINATION OF NITRATE IN SEA WATER [J].
CHOW, TJ ;
JOHNSTONE, MS .
ANALYTICA CHIMICA ACTA, 1962, 27 (05) :441-&
[2]  
CLESCERI LS, 1998, STANDARD METHOD EXAM, P4112
[3]  
Fukushi K, 2002, ELECTROPHORESIS, V23, P1928, DOI 10.1002/1522-2683(200206)23:12<1928::AID-ELPS1928>3.0.CO
[4]  
2-K
[5]   Micro-phase sorbent extraction for trace analysis via in situ sorbent formation:: Application to the spectrophotometric determination of nitrite in environmental waters [J].
Hata, N ;
Kawashima, M ;
Kasahara, I ;
Taguchi, S .
ANALYTICAL SCIENCES, 2003, 19 (02) :239-243
[6]   Flow-injection spectrophotometric determination of nitrite and nitrate in biological samples [J].
Higuchi, K ;
Motomizu, S .
ANALYTICAL SCIENCES, 1999, 15 (02) :129-134
[7]   Sensitive flow injection colorimetry of nitrite by catalytic coupling of N-phenyl-p-phenylenediamine with N,N-dimethylaniline [J].
Kadowaki, R ;
Nakano, S ;
Kawashima, T .
TALANTA, 1999, 48 (01) :103-107
[8]   Simultaneous determination of nitrate and nitrite in human plasma by gas chromatography-mass spectrometry [J].
Kage, S ;
Kudo, K ;
Ikeda, N .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2002, 26 (06) :320-324
[9]   AUTOMATED ANALYSIS FOR NITRATE BY HYDRAZINE REDUCTION [J].
KAMPHAKE, LJ ;
HANNAH, SA ;
COHEN, JM .
WATER RESEARCH, 1967, 1 (03) :205-&
[10]   Flow-injection analysis method for the determination of nitrite and nitrate in natural water samples using a chemiluminescence NOx monitor [J].
Kanda, Y ;
Taira, M .
ANALYTICAL SCIENCES, 2003, 19 (05) :695-699