The impact of fiducial distribution on headset-based registration in image-guided sinus surgery

被引:20
作者
Knott, PD
Maurer, CR
Gallivan, R
Roh, HJ
Citardi, MJ
机构
[1] Cleveland Clin Fdn, Dept Otolaryngol & Communicat Dis, Head & Neck Inst, Cleveland, OH 44195 USA
[2] Stanford Univ, Dept Neurosurg, Image Guidance Labs, Stanford, CA 94305 USA
[3] Pusan Natl Univ Hosp, Dept Otolaryngol, Pusan, South Korea
关键词
D O I
10.1016/j.otohns.2004.03.045
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
OBJECTIVE: The objective of this study was to assess registration error due to fiducial configuration for the ENT headsets for the CBYON Suite (CBYON, Mountain View, CA) and InstaTrak (GEMS Navigation and Visualization, Waukesha, WI). STUDY DESIGN: Axial CT scans (1-mm slice thickness) were obtained of for 24 cadaveric heads using the CBYON headset and for 23 cadaveric heads using the GEMS headset. The CBYON and GEMS NAV software were used to calculate the fiducial registration error (FRE). Fiducial localization error (FLE) was estimated from FRE. Theoretical target registration error (TRE) was calculated at 11 targets. RESULTS: The FRE for CBYON and GEMS NAV was 0.69 mm and 0.27 mm, respectively. The theoretical TRE for CBYON and GEMS NAV was 0.41 mm and 0.30 mm, respectively. The theoretical TRE was greater at targets posterior in the sinus cavities. CONCLUSION: Theoretical TRE values for both ENT headsets are less than clinically observed TRE. Clinically observed TRE is likely due to repositioning accuracy. EBM rating: B-2.
引用
收藏
页码:666 / 672
页数:7
相关论文
共 12 条
  • [1] Making image guidance work: Understanding control of accuracy
    Berry, J
    O'Malley, BW
    Humphries, S
    Staecker, H
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2003, 112 (08) : 689 - 692
  • [2] Fitzpatrick J.M., 2000, Handbook of Medical Imaging, VII, P447, DOI DOI 10.1117/3.831079.CH8
  • [3] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [4] Image-guided endoscopic surgery: Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system
    Fried, MP
    Kleefield, J
    Gopal, H
    Reardon, E
    Ho, BT
    Kuhn, FA
    [J]. LARYNGOSCOPE, 1997, 107 (05) : 594 - 601
  • [5] Henderson JM, 2003, NEUROSURGERY, V52, P99
  • [6] Stereotactic computer-assisted navigational sinus surgery: Accuracy of an electromagnetic tracking system with the tissue debrider and when utilizing different headsets for the same patient
    Javer, AR
    Kuhn, FA
    Smith, D
    [J]. AMERICAN JOURNAL OF RHINOLOGY, 2000, 14 (06): : 361 - 365
  • [7] Koele W, 2002, RHINOLOGY, V40, P1
  • [8] Registration of head volume images using implantable fiducial markers
    Maurer, CR
    Fitzpatrick, JM
    Wang, MY
    Galloway, RL
    Maciunas, RJ
    Allen, GS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (04) : 447 - 462
  • [9] MAURER CR, 2002, ADV TECHNIQUES IMAGE, P10
  • [10] Image-guided functional endoscopic sinus surgery
    Olson, G
    Citardi, MJ
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2000, 123 (03) : 188 - 194