US-guided transthoracic cutting biopsy for peripheral thoracic lesions less than 3 cm in diameter

被引:80
作者
Liao, WY
Chen, MZ
Chang, YL
Wu, HD
Yu, CJ
Kuo, PH
Yang, PC
机构
[1] Natl Taiwan Univ Hosp, Dept Internal Med, Div Chest Med, Taipei 100, Taiwan
[2] Far Eastern Mem Hosp, Taipei 100, Taiwan
关键词
biopsies; technology; neoplasms; diagnosis; thorax; biopsy; ultrasound; (US); guidance;
D O I
10.1148/radiology.217.3.r00dc21685
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To evaluate the safety and accuracy of ultrasonography (US)-guided transthoracic cutting biopsy for diagnosing peripheral thoracic lesions (< 3 cm). MATERIALS AND METHODS: Fifty consecutive patients with peripheral thoracic lesions less than 3 cm in diameter underwent US-guided percutaneous transthoracic cutting biopsy with a modified technique. Fifty lesions (43 parenchymal lung, two pleural, two chest wall, and three anterior mediastinal lesions) were sampled for biopsy. The final diagnosis was based on histopathologic analysis of surgical specimens (n = 18) or clinical follow-up (n = 32). RESULTS: The histology recovery rate was 98% (49 lesions), and the correct diagnosis was obtained in 48 lesions (96%). Twenty-four (48%) lesions were malignant and 26 (52%) were benign. The diagnostic accuracy for malignant lesions was 92% (22 of 24 lesions). A specific benign diagnosis was made in 17 (65%) of the 26 benign lesions, and the negative predictive value for malignancy was 93% (26 of 28 lesions). Only two patients (4%) developed postbiopsy pneumothorax, and three (6%) developed postbiopsy hemoptysis. Biopsy helped prevent surgery or thoracoscopy in 32 patients (64%): 18 patients with benign disease and 14 with multiple metastases or inoperable cancer. CONCLUSION: US-guided transthoracic cutting biopsy appears to be a safe and effective method for diagnosing peripheral thoracic lesions less than 3 cm in diameter. The high diagnostic accuracy for benign lesions and metastatic lung cancer can help prevent surgery in many cases.
引用
收藏
页码:685 / 691
页数:7
相关论文
共 37 条
[1]
CT-guided transthoracic needle biopsy: A comparison between automated biopsy gun and fine needle aspiration [J].
Arakawa, H ;
Nakajima, Y ;
Kurihara, Y ;
Niimi, H ;
Ishikawa, T .
CLINICAL RADIOLOGY, 1996, 51 (07) :503-506
[2]
VALUE OF HAVING A CYTOPATHOLOGIST PRESENT DURING PERCUTANEOUS FINE-NEEDLE ASPIRATION BIOPSY OF LUNG - REPORT OF 55 CANCER-PATIENTS AND METAANALYSIS OF THE LITERATURE [J].
AUSTIN, JHM ;
COHEN, MB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (01) :175-177
[3]
THE CLINICAL OUTCOME OF NEEDLE ASPIRATIONS OF THE LUNG WHEN CANCER IS NOT DIAGNOSED [J].
CALHOUN, P ;
FELDMAN, PS ;
ARMSTRONG, P ;
BLACK, WC ;
POPE, TL ;
MINOR, GR ;
DANIEL, TM .
ANNALS OF THORACIC SURGERY, 1986, 41 (06) :592-596
[4]
CUMMINGS SR, 1986, AM REV RESPIR DIS, V134, P449
[5]
Real-time CT fluoroscopy: Evolution of an interventional tool [J].
Daly, B ;
Templeton, PA .
RADIOLOGY, 1999, 211 (02) :309-315
[6]
FRASER RS, 1991, ARCH PATHOL LAB MED, V115, P751
[7]
THIN-NEEDLE ASPIRATION BIOPSY - METHODS OF INCREASING THE ACCURACY OF A NEGATIVE PREDICTION [J].
GOBIEN, RP ;
VALICENTI, JF ;
PARIS, BS ;
DANIELL, C .
RADIOLOGY, 1982, 145 (03) :603-605
[8]
CT-GUIDED CUTTING-NEEDLE BIOPSIES OF SELECTED CHEST LESIONS [J].
GORALNIK, CH ;
OCONNELL, DM ;
ELYOUSEF, SJ ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) :903-907
[9]
SUPPLEMENTARY TISSUE-CORE HISTOLOGY FROM FINE-NEEDLE TRANS-THORACIC ASPIRATION BIOPSY [J].
GREENE, R ;
SZYFELBEIN, WM ;
ISLER, RJ ;
STARK, P ;
JANTSCH, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (04) :787-792
[10]
CT-guided biopsy of pulmonary nodules less than 3 cm: Usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis [J].
Hayashi, N ;
Sakai, T ;
Kitagawa, M ;
Kimoto, T ;
Inagaki, R ;
Ishii, Y ;
Noriki, S ;
Imamura, Y .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :329-331