cable models;
400-Hz power supply;
ground power units (GPUs);
identification;
uninterruptible power supply (UPS);
D O I:
10.1109/TIA.2004.834110
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
In this paper a new cable voltage drop compensation scheme for ground power units (GPUs) is presented. The scheme is able to predict and compensate the voltage drop in an output cable by measuring the current quantities at the source.,The prediction is based on an advanced cable model that includes self- and mutual impedance parameters. The model predicts the voltage drop at both symmetrical and unbalanced loads. In order to determine the cable model parameters an automatic identification concept is derived. The concept is tested in full scale on a 90-kVA 400-Hz GPU with two different cables. It is concluded that the performance is significantly improved both with symmetrical and unsymmetrical cables and with balanced and unbalanced loads.