Risk factors for acute and subacute stent thrombosis after high-pressure stent implantation: A study by intracoronary ultrasound

被引:20
作者
Werner, GS [1 ]
Gastmann, O [1 ]
Ferrari, M [1 ]
Schuenemann, S [1 ]
Knies, A [1 ]
Diedrich, J [1 ]
Kreuzer, H [1 ]
机构
[1] Univ Gottingen, Dept Cardiol, Ctr Internal Med, D-37075 Gottingen, Germany
关键词
D O I
10.1016/S0002-8703(98)70097-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In the era of coronary stenting with high-pressure expansion, stent thrombosis remains a major life-threatening risk. Because of its superior imaging mode, intracoronary ultrasound could provide insight into potential risk factors for stent thrombosis. Patients and Methods In 215 patients with stent implantations controlled by intracoronary ultrasound, four occurrences of subacute stent thrombosis, two complete acute thrombotic occlusions, and four occurrences of incomplete acute thrombosis were observed. All scents were expanded with inflation pressures of at least 14 atm (17 +/- 3 atm). The clinical data and the qualitative and quantitative ultrasound information were compared between stents with thrombosis and stents without thrombosis. The luminal area and the plaque harder of the reference segments, and of the smallest and largest site of the stented segment after the initial and final expansion, were measured. Results Stents in the left anterior descending artery were more often involved in stent thrombosis than other vessels, but the vessel dimensions in this target vessel were smaller than in the right coronary artery. The plaque burden was considerably larger after stent implantation with subsequent thrombosis compared with no thrombosis (74.1 +/- 8.8% vs 63.6 +/- 8.0%; p < 0.001), and the stent area was smaller (4.80% +/- 1.33 mm(2) vs 6.86 +/- 2.08 mm(2); P < 0.01). In stents with thrombosis the plaque burden of the stent site with the smallest and largest lumen differed by 15.2%, whereas the difference in plaque burden in stents without thrombosis was 2.7%. Intracoronary ultrasound showed that the best risk predictor of thrombosis was the residual plaque burden of the stented segment (odds ratio 15.7 [confidence interval 2.4 to 104.7]), and a small stent area after implantation (odds ratio 6.8 [confidence interval 1.9 to 24.3]). Conclusion in a multivariate risk analysis plaque burden was the strongest independent risk factor for stent thrombosis. The amount of residual plaque mass around the stent might be a potential trigger for thrombus formation.
引用
收藏
页码:300 / 309
页数:10
相关论文
共 37 条
[1]   PREDICTORS OF THROMBOTIC COMPLICATIONS AFTER PLACEMENT OF THE FLEXIBLE COIL STENT [J].
AGRAWAL, SK ;
HO, DSW ;
LIU, MW ;
IYER, S ;
HEARN, JA ;
CANNON, AD ;
MACANDER, PJ ;
DEAN, LS ;
BAXLEY, WA ;
ROUBIN, GS .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (16) :1216-1219
[2]   CORONARY STENTING FOR ACUTE MYOCARDIAL-INFARCTION [J].
AHMAD, T ;
WEBB, JG ;
CARERE, RR ;
DODEK, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (01) :77-80
[3]   Identification of coronary thrombus after myocardial infarction by intracoronary ultrasound compared with histology of tissues sampled by atherectomy [J].
ChemarinAlibelli, MJ ;
Pieraggi, MT ;
Elbaz, M ;
Carrie, D ;
Fourcade, J ;
Puel, J ;
Tobis, JM .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (05) :344-349
[4]   A NOVEL STRATEGY FOR STENT DEPLOYMENT IN THE TREATMENT OF ACUTE OR THREATENED CLOSURE COMPLICATING BALLOON CORONARY ANGIOPLASTY - USE OF SHORT OR STANDARD (OR BOTH) SINGLE OR MULTIPLE PALMAZ-SCHATZ STENTS [J].
COLOMBO, A ;
GOLDBERG, SL ;
ALMAGOR, Y ;
MAIELLO, L ;
FINCI, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) :1887-1891
[5]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[6]  
De Jaegere Peter, 1996, Journal of the American College of Cardiology, V27, p137A
[7]  
EECKHOUT E, 1995, BRIT HEART J, V74, P592
[8]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[9]   THROMBOSIS AND RESTENOSIS AFTER STENTING IN FAILED ANGIOPLASTY - COMPARISON WITH ELECTIVE STENTING [J].
FOLEY, JB ;
BROWN, RIG ;
PENN, IM .
AMERICAN HEART JOURNAL, 1994, 128 (01) :12-20