Surface immobilization of catalytic beacons based on ratiometric fluorescent DNAzyme sensors: A systematic study

被引:38
作者
Wernette, Daryl P.
Mead, Carolyn
Bohn, Paul W.
Lu, Yi [1 ]
机构
[1] Univ Notre Dame, Dept Chem & Biomol Engn, Notre Dame, IN 46556 USA
[2] Univ Notre Dame, Dept Chem, Notre Dame, IN 46556 USA
[3] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[4] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
关键词
D O I
10.1021/la701303k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
DNAzyme-based catalytic beacons have the potential for sensing a large number of relevant analytes. Thus, a systematic investigation of factors affecting their performance when immobilized into gold-coated nanocapillary array membranes (NCAMs) was undertaken. Enzyme immobilization times were varied to determine that as little as 15 min was sufficient for ratiometric detection of Pb2+-specific activity, while immobilization density saturated after 1.5 h. Immobilization of the DNAzymes into NCAMs with 600 nm pore size resulted in higher immobilization efficiency and higher enzymatic activity than that with 200 nm pore size. A poly-T linker length between the tethering thiol and first oligonucleotide, used to extend the DNAzyme above the backfilling mercaptohexanol (MCH) monolayer, had no effect on DNAzyme activity. The backfilling method of immobilization, involving backfilling followed by hybridization, was found most effective for DNAzyme activity compared to immobilization of hybridized DNAzyme complex (a 67% loss of activity) or concurrent enzyme and MCH immobilization (75% loss of activity). The backfilling MCH monolayer provided similar to 3.5 times increase in activity compared to DNAzyme assembled without MCH, and was over 5 times more active than shorter and longer backfilling molecules tested. The immobilized DNAzyme retained its optimized performance at 50 mM NaCl. Finally, the generalized immobilization and ratiometric procedure was employed for a uranyl-specific DNAzyme with 25 +/- 15 times increase in ratio observed. These findings form a firm basis on which practical applications of catalytic beacons can be realized, including sensors for both Pb2+ and UO22+ ions.
引用
收藏
页码:9513 / 9521
页数:9
相关论文
共 77 条
[1]   Structure-switching allosteric deoxyribozymes [J].
Achenbach, JC ;
Nutiu, R ;
Li, YF .
ANALYTICA CHIMICA ACTA, 2005, 534 (01) :41-51
[2]   Controlling the adsorption and reactivity of DNA on gold [J].
Aqua, T ;
Naaman, R ;
Daube, SS .
LANGMUIR, 2003, 19 (25) :10573-10580
[3]   The role of surface charging during the coadsorption of mercaptohexanol to DNA layers on gold: Direct observation of desorption and layer reorientation [J].
Arinaga, K. ;
Rant, U. ;
Tornow, M. ;
Fujita, S. ;
Abstreiter, G. ;
Yokoyama, N. .
LANGMUIR, 2006, 22 (13) :5560-5562
[4]  
Beerlage MAM, 2000, J APPL POLYM SCI, V75, P1180, DOI 10.1002/(SICI)1097-4628(20000228)75:9<1180::AID-APP12>3.0.CO
[5]  
2-P
[6]   Engineered allosteric ribozymes as biosensor components [J].
Breaker, RR .
CURRENT OPINION IN BIOTECHNOLOGY, 2002, 13 (01) :31-39
[7]   A lead-dependent DNAzyme with a two-step mechanism [J].
Brown, AK ;
Li, J ;
Pavot, CMB ;
Lu, Y .
BIOCHEMISTRY, 2003, 42 (23) :7152-7161
[8]   Characterization of a DNA-cleaving deoxyribozyme [J].
Carmi, N ;
Breaker, RR .
BIOORGANIC & MEDICINAL CHEMISTRY, 2001, 9 (10) :2589-2600
[9]   Efficient signaling platforms built from a small catalytic DNA and doubly labeled fluorogenic substrates [J].
Chiuman, William ;
Li, Yingfu .
NUCLEIC ACIDS RESEARCH, 2007, 35 (02) :401-405
[10]   HINDERED TRANSPORT OF LARGE MOLECULES IN LIQUID-FILLED PORES [J].
DEEN, WM .
AICHE JOURNAL, 1987, 33 (09) :1409-1425