The Trabecular Metal Monoblock acetabular component in patients with high congenital hip dislocation A PROSPECTIVE STUDY

被引:34
作者
Macheras, G. A. [1 ]
Kateros, K. [1 ]
Koutsostathis, S. D. [1 ]
Tsakotos, G. [1 ]
Galanakos, S. [1 ]
Papadakis, S. A. [1 ]
机构
[1] KAT Gen Hosp, Dept Orthopaed, Athens 14561, Greece
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2010年 / 92B卷 / 05期
关键词
LOW-FRICTION ARTHROPLASTY; DEVELOPMENTAL DYSPLASIA; FOLLOW-UP; IMPLANT MIGRATION; BONE-GRAFT; REPLACEMENT; DISEASE; EBRA; RECONSTRUCTION; INTERFACE;
D O I
10.1302/0301-620X.92B5.23256
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Between November 1997 and December 2000 we performed 27 total hip replacements in 22 patients with high congenital dislocation of the hip using porous tantalum monoblock acetabular components implanted in the true acetabular bed. Clinical and radiological evaluation was performed at regular intervals for a mean of 10.2 years (8.5 to 12). The mean Harris Hip Score improved from 48.3 (15 to 65) pre-operatively to 89.5 (56 to 100) at the final follow-up. The mean Oxford Hip Score was 49.5 (35 to 59) pre-operatively and decreased to 21.2 (12 to 48) at one year and 15.2 (10 to 28) at final follow-up. Migration of the acetabular component was assessed with the EBRA software system. There was a mean migration of 0.68 mm (0.49 to 0.8) in the first year and a mean 0.89 mm (0.6 to 0.98) in the second year, after excluding one initial excessive migration. No revision was necessary for any reason, no acetabular component became loose, and no radiolucent lines were observed at the final follow-up. The porous tantalum monoblock acetabular component is an implant offering adequate initial stability in conjunction with a modulus of elasticity and porosity close to that of cancellous bone. It favours bone ingrowth, leading to good mid-term results.
引用
收藏
页码:624 / 628
页数:5
相关论文
共 48 条
[1]
Anatomy of the dysplastic hip and consequences for total hip arthroplasty [J].
Argenson, Jean-Noel A. ;
Flecher, Xavier ;
Parratte, Sebastien ;
Aubaniac, Jean-Manuel .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :40-45
[2]
BOBYN JD, 1980, CLIN ORTHOP RELAT R, P263
[3]
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[4]
Tissue response to porous tantalum acetabular cups - A canine model [J].
Bobyn, JD ;
Toh, KK ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF ARTHROPLASTY, 1999, 14 (03) :347-354
[5]
LOW-FRICTION ARTHROPLASTY IN CONGENITAL SUBLUXATION OF HIP [J].
CHARNLEY, J ;
FEAGIN, JA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1973, (91) :98-113
[6]
Long-term survival of the acetabular component after total hip arthroplasty with cement in patients with developmental dysplasia of the hip [J].
Chougle, A ;
Hemmady, MV ;
Hodgkinson, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (01) :71-79
[7]
Incidence and Characteristics of Femoral Deformities in the Dysplastic Hip [J].
Clohisy, John C. ;
Nunley, Ryan M. ;
Carlisle, Jack C. ;
Schoenecker, Perry L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :128-134
[8]
TOTAL HIP-REPLACEMENT IN CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP [J].
CROWE, JF ;
MANI, VJ ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (01) :15-23
[9]
Questionnaire on the perceptions of patients about total hip replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Carr, A ;
Murray, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :185-190
[10]
Reliability of the Crowe und Hartofilakidis classifications used in the assessment of the adult dysplastic hip [J].
Decking, R ;
Brunner, A ;
Decking, J ;
Puhl, W ;
Günther, KP .
SKELETAL RADIOLOGY, 2006, 35 (05) :282-287