A novel iterative method for lesion delineation and volumetric quantification with FDG PET

被引:96
作者
van Dalen, Jorn A.
Hoffmann, Aswin L.
Dicken, Volker
Vogel, Wouter V.
Wiering, Bastiaan
Ruers, Theo J.
Karssemeijer, Nico
Oyen, Wim J. G.
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Surg, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen Med Ctr, Dept Radiol, NL-6500 HB Nijmegen, Netherlands
[3] MeVis Ctr Med Diagnost Syst & Visualisat, Bremen, Germany
关键词
PET; lesion delineation; volumetric quantification; thresholding;
D O I
10.1097/MNM.0b013e328155d154
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The determination of lesion boundaries on FDG PET is difficult due to the point-spread blurring and unknown uptake of activity within a lesion. Standard threshold-based methods for volumetric quantification on PET usually neglect any size dependence and are biased by dependence on the signal-to-background ratio (SBR). A novel, model-based method is hypothesized to provide threshold levels independent f the SBR and to allow accurate measurement of volumes down to the resolution of the PET scanner. Methods A background-subtracted relative-threshold level (RTL) method was derived, based on a convolution of the point-spread function and a sphere with diameter D. Validation of the RTL method was performed using PET imaging of a Jaszczak phantom with seven hollow spheres (D = 10-60 mm). Activity concentrations for the background and spheres (signal) were varied to obtain SBRs of 1.5-10. An iterative procedure was introduced for volumetric quantification, as the optimal RTL depends on a priori knowledge of the volume. The feasibility of the RTL method was tested in two patients with liver metastases and compared to a standard method using a fixed percentage of the signal. Results Phantom data validated that the theoretically optimal RTL depends on the sphere size, but not on the SBR. Typically, RTL=40% (D=15-60mm), and RTL > 50% for small spheres (D < 12 mm). The RTL method is better applicable to patient data than the standard method. Conclusions Based on an iterative procedure, the RTL method has been shown to provide optimal threshold levels independent of the SBR and to be applicable in phantom and in patient studies. It is a promising tool for lesion delineation and volumetric quantification of PET lesions.
引用
收藏
页码:485 / 493
页数:9
相关论文
共 29 条
[1]  
Antoch G, 2005, J NUCL MED, V46, P520
[2]   Defining a radiotherapy target with positron emission tomography [J].
Black, QC ;
Grills, IS ;
Kestin, LL ;
Wong, CYO ;
Wong, JW ;
Martinez, AA ;
Yan, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1272-1282
[3]   Results of radio frequency ablation of primary and secondary liver tumors: Long-term follow-up with computed tomography and positron emission tomography-18F-deoxyfluoroglucose scanning [J].
Blokhuis, TJ ;
van der Schaaf, NC ;
van den Tol, MP ;
Comans, EFI ;
Manoliu, RA ;
van der Sijp, JRM .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2004, 39 :93-97
[4]   Informatics in radiology (infoRAD) -: New tools for computer assistance in thoracic CT -: Part 2.: Therapy monitoring of pulmonary metastases [J].
Bornemann, L ;
Kuhnigk, JM ;
Dicken, V ;
Zidowitz, S ;
Kuemmerlen, B ;
Krass, S ;
Peitgen, HO ;
Wein, BB ;
Schubert, H ;
Shin, HO ;
Wormanns, D .
RADIOGRAPHICS, 2005, 25 (03) :841-848
[5]   Abdominal organ motion measured using 4D CT [J].
Brandner, Edward D. ;
Wu, Andrew ;
Chen, Hungcheng ;
Heron, Dwight ;
Kalnicki, Shalom ;
Komanduri, Krishna ;
Gerszten, Kristina ;
Burton, Steve ;
Ahmed, Irfan ;
Shou, Zhenyu .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :554-560
[6]   Radiofrequency thermal ablation of liver tumors [J].
Buscarini, E ;
Savoia, A ;
Brambilla, G ;
Menozzi, F ;
Reduzzi, L ;
Strobel, D ;
Hänsler, J ;
Buscarini, L ;
Gaiti, L ;
Zambelli, A .
EUROPEAN RADIOLOGY, 2005, 15 (05) :884-894
[7]   Automated functional image-guided radiation treatment planning for rectal cancer [J].
Ciernik, IF ;
Huser, M ;
Burger, C ;
Davis, JB ;
Szekely, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :893-900
[8]   Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT):: A feasibility study [J].
Ciernik, IF ;
Dizendorf, E ;
Baumert, BG ;
Reiner, B ;
Burger, C ;
Davis, JB ;
Lütolf, UM ;
Steinert, HC ;
Von Schulthess, GK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :853-863
[9]   Tumor volume in pharyngolaryngeal squamous cell carcinoma:: Comparison at CT, MR imaging, and FDG PET and validation with surgical specimen [J].
Daisne, JF ;
Duprez, T ;
Weynand, B ;
Lonneux, M ;
Hamoir, M ;
Reychler, H ;
Grégoire, V .
RADIOLOGY, 2004, 233 (01) :93-100
[10]   Tri-dimensional automatic segmentation of PET volumes based on measured source-to-background ratios:: influence of reconstruction algorithms [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Doumont, T ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :247-250