In vitro and in vivo studies on continuous echo-contrast application strategies using sonovue in a newly developed rotating pump setup

被引:18
作者
Lohmaier, S
Ghanem, A
Veltmann, C
Sommer, T
Bruce, M
Tiemann, K
机构
[1] Univ Bonn, Med Klin 2, Dept Internal Med & Cardiol, D-53105 Bonn, Germany
[2] Univ Bonn, Dept Radiol, Bonn, Germany
[3] Philips Ultrasound, Bothell, WA USA
关键词
contrast echocardiography; myocardial perfusion; constant infusion; power pulse inversion; SonoVue;
D O I
10.1016/j.ultrasmedbio.2004.07.019
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
With emerging imaging strategies for contrast sonography (CS), there is a rising demand for the precise control of ultrasound (US) contrast agent delivery. Constant delivery minimizes artefacts and improves efficacy. The aim of this study was to evaluate the physical properties of the new contrast agent SonoVue and to evaluate the feasibility and accuracy of a new infusion approach using an automated infusion system for contrast agitation and delivery of echo-contrast agents. In vitro testing of infusion properties of SonoVue were performed in a capillary phantom mimicking tissue perfusion. Nonagitated standard infusion setups were compared with hand agitation and the new pump system with respect to possible artefacts, constancy of contrast effect and efficacy. In three volunteers, the new pump system was tested for constancy of contrast in large vessels. Without continuous agitation, continuous infusion of SonoVue resulted in bolus-like signal-intensity curves, along with substantial imaging artefacts. Additionally, homogenization of SonoVue significantly improved efficacy (p < 0.0001). No significant differences were found between hand agitation and homogenization by the new pump. In clinical settings, constant agitation using the new pump resulted in constant signal conditions in the carotid artery 3.72 +/- 0.46 units (U) after 5 min. Continuous agitation of SonoVue is mandatory for quantitative approaches. By the new infusion technique, CS could be performed for a reasonably long time period and efficacy is significantly improved (p < 0.0001). The new infusion technique might thereby allow routine application of constant infusion scenarios in clinical CS. (E-mail: k-tiemann@uni-bonn.de) (C) 2004 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1145 / 1151
页数:7
相关论文
共 19 条
[1]   Comparison of bolus and infusion of the ultrasound contrast agent Levovist fur colour Doppler ultrasound of renal arteries [J].
Albrecht, T ;
Cosgrove, DO ;
Butler-Barnes, J ;
Jayaram, V ;
Mahler, M ;
Urbank, A ;
Bauer, A .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (10) :824-829
[2]   Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion:: Preliminary experience [J].
Albrecht, T ;
Urbank, A ;
Mahler, M ;
Bauer, A ;
Doré, CJ ;
Blomley, MJK ;
Cosgrove, DO ;
Schlief, R .
RADIOLOGY, 1998, 207 (02) :339-347
[3]   Blood flow assessment by ultrasound-induced destruction of echocontrast agents using harmonic power Doppler imaging:: Which parameters determine contrast replenishment curves? [J].
Köster, J ;
Schlosser, T ;
Pohl, C ;
Lentz, C ;
Lohmaier, S ;
Veltmann, C ;
Kuntz-Hehner, S ;
Omran, H ;
Lüderitz, B ;
Becher, H ;
Tiemann, K .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (01) :1-8
[4]   Continuous-infusion contrast-enhanced US: In vitro studies of infusion techniques with different contrast agents [J].
Kuntz-Hehner, S ;
Goenechea, J ;
Pohl, C ;
Schlosser, T ;
Veltmann, C ;
Lentz, C ;
Lohmaier, S ;
Ehlgen, A ;
Omran, H ;
Becher, H ;
Tiemann, K .
RADIOLOGY, 2001, 220 (03) :647-654
[5]  
Lafitte S, 2001, J AM SOC ECHOCARDIOG, V14, P1010
[6]   In vitro, animal, and human characterization of OPTISON infusions for myocardial contrast echocardiography [J].
Miller, JJ ;
Tiemann, K ;
Podell, S ;
Stevens, JKD ;
Kuvelas, T ;
Greener, Y ;
Killam, AL ;
Goenechea, J ;
Dittrich, HC ;
Becher, H .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (12) :1027-1034
[7]   An investigation of the relationship between ultrasound echo enhancement and Doppler frequency shift using a pulsatile arterial flow phantom [J].
Petrick, J ;
Zomack, M ;
Schlief, R .
INVESTIGATIVE RADIOLOGY, 1997, 32 (04) :225-235
[8]  
Podell S, 1999, BIOTECHNOL APPL BIOC, V30, P213
[9]   Feasibility of the flash-replenishment concept in renal tissue:: Which parameters affect the assessment of the contrast replenishment? [J].
Schlosser, T ;
Pohl, C ;
Veltmann, C ;
Lohmaier, S ;
Goenechea, J ;
Ehlgen, A ;
Köster, J ;
Bimmel, D ;
Kuntz-Hehner, S ;
Becher, H ;
Tiemann, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (07) :937-944
[10]   BR1 - A NEW ULTRASONOGRAPHIC CONTRAST AGENT BASED ON SULFUR HEXAFLUORIDE-FILLED MICROBUBBLES [J].
SCHNEIDER, M ;
ARDITI, M ;
BARRAU, MB ;
BROCHOT, J ;
BROILLET, A ;
VENTRONE, R ;
YAN, F .
INVESTIGATIVE RADIOLOGY, 1995, 30 (08) :451-457