Dipole source localization by means of maximum likelihood estimation I.: Theory and simulations

被引:53
作者
Lütkenhöner, B [1 ]
机构
[1] Univ Munster, Inst Expt Audiol, D-48129 Munster, Germany
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1998年 / 106卷 / 04期
关键词
dipole source localization; maximum-likelihood estimation; magnetoencephalography; localization errors; random dipoles;
D O I
10.1016/S0013-4694(97)00140-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
By analyzing simulated neuromagnetic recordings with a 37 channel magnetometer system, it was shown that the accuracy of a dipole source localization is considerably improved if the standard least-squares fit procedure is replaced by a maximum likelihood estimation accounting for the covariances of the noise in the measurement channels. Spatially correlated noise was generated by random dipoles homogeneously distributed in a sphere representing the brain. The study suggests that a maximum likelihood estimation reduces the standard deviations of the estimated dipole parameters by roughly a factor of two. (C) 1998 Elsevier Science ireland Ltd.
引用
收藏
页码:314 / 321
页数:8
相关论文
共 16 条
[1]   MAGNETIC SOURCE IMAGING - A REVIEW OF THE MAGNES SYSTEM OF BIOMAGNETIC TECHNOLOGIES INCORPORATED [J].
BENZEL, EC ;
LEWINE, JD ;
BUCHOLZ, RD ;
ORRISON, WW .
NEUROSURGERY, 1993, 33 (02) :252-259
[2]  
Golub G.H., 1996, Matrix Computations, Vthird
[3]   MAGNETOENCEPHALOGRAPHY - THEORY, INSTRUMENTATION, AND APPLICATIONS TO NONINVASIVE STUDIES OF THE WORKING HUMAN BRAIN [J].
HAMALAINEN, M ;
HARI, R ;
ILMONIEMI, RJ ;
KNUUTILA, J ;
LOUNASMAA, OV .
REVIEWS OF MODERN PHYSICS, 1993, 65 (02) :413-497
[4]   SPATIAL-RESOLUTION OF NEUROMAGNETIC RECORDS - THEORETICAL CALCULATIONS IN A SPHERICAL MODEL [J].
HARI, R ;
JOUTSINIEMI, SL ;
SARVAS, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 71 (01) :64-72
[5]  
KAUKORANTA E, 1986, EXP BRAIN RES, V63, P60
[6]  
KNUUTILA J, 1988, BIOMAGNETISM 87, P186
[7]   The resolution-field concept [J].
Lutkenhoner, B ;
Menendez, RGDP .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (04) :326-334
[8]   Current dipole localization with an ideal magnetometer system [J].
Lutkenhoner, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (11) :1049-1061
[9]   Dipole source localization by means of maximum likelihood estimation.: II.: Experimental evaluation [J].
Lütkenhöner, B .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (04) :322-329
[10]   MAGNETIC-FIELD ARISING FROM CURRENT DIPOLES RANDOMLY DISTRIBUTED IN A HOMOGENEOUS SPHERICAL VOLUME CONDUCTOR [J].
LUTKENHONER, B .
JOURNAL OF APPLIED PHYSICS, 1994, 75 (11) :7204-7210