Heparin-coated stent placement for the treatment of stenoses in small coronary arteries of symptomatic patients

被引:78
作者
Haude, M
Konorza, TFM
Kalnins, U
Erglis, A
Saunamäki, K
Glogar, HD
Grube, E
Gil, R
Serra, A
Richardt, HG
Sick, P
Erbel, R
机构
[1] Univ Essen Gesamthsch, Kardiol Klin, D-45122 Essen, Germany
[2] P Stradins Univ Hosp, Riga, Latvia
[3] Rigshosp, Hjertecentret, DK-2100 Copenhagen, Denmark
[4] Allgemeines Krankenhaus Wien, Vienna, Austria
[5] Krankenhaus Siegburg GmbH, Siegburg, Germany
[6] Pomorskiej Akad Med Hemodynam Elektrofizjol 1, Szczecin, Poland
[7] Hosp Clin Barcelona, Provincial Serv Hemodinam Cardiaca 1, Barcelona, Spain
[8] Med Univ Lubeck, Dept Cardiol, D-23538 Lubeck, Germany
[9] Univ Leipzig, Heart Ctr GmbH, Leipzig, Germany
关键词
stents; angioplasty; heparin; restenosis;
D O I
10.1161/01.CIR.0000053442.64637.34
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The role of stents, especially of heparin-coated stents for the treatment of stenoses in small coronary arteries, is still unclear. Therefore, we performed this prospective, randomized trial to evaluate the angiographic and clinical outcome after treatment of stenoses in small coronary arteries (2.0 to 2.6 mm) of symptomatic patients. Methods and Results-We randomly assigned 588 patients to angioplasty (n=195), bare stenting (n=196), or heparin-coated stenting (n=197). The primary end point was minimal lumen diameter (MLD) at 6 months. With comparable baseline parameters, the two stent arms showed a larger postinterventional MLD, larger acute gain, and smaller residual percent diameter stenosis, although a residual stenosis of 12+/-16% was achieved in the angioplasty arm, including a 27% crossover rate to stenting. Eighty percent of patients had follow-up angiography, which documented a borderline significantly larger MLD and smaller percent diameter stenosis for the two stent groups (1.34+/-0.48 mm and 42+/-20% after angioplasty, 1.47+/-0.48 mm and 36+/-20% after bare stenting, and 1.45+/-0.54 mm and 38+/-23% after heparin-coated stenting; P=0.049 and P=0.038, respectively), but restenosis rates were not different (32%, 25%, and 30%). Thrombotic events occurred in 1.0% after angioplasty and 0.5% after bare or heparin-coated stenting. Survival without myocardial infarction or target vessel revascularization at 250 days was 84.6% (angioplasty), 88.3% (bare stenting), and 88.3% (heparin-coated stenting; log-rank P=0.39). Conclusion-Compared with angioplasty with provisional stenting, bare and heparin- coated stenting confer superior angiographic results and a nonsignificant 24% reduction in clinical events, with no difference between bare and heparin- coated stenting in the treatment of stenoses in small coronary arteries.
引用
收藏
页码:1265 / 1270
页数:6
相关论文
共 27 条
[1]  
Abizaid Alexandre, 2001, Curr Interv Cardiol Rep, V3, P1
[2]   Angiographic and clinical outcome following coronary stenting of small vessels - A comparison with coronary stenting of large vessels [J].
Akiyama, T ;
Moussa, I ;
Reimers, B ;
Ferraro, M ;
Kobayashi, Y ;
Blengino, S ;
Di Francesco, L ;
Finci, L ;
Di Mario, C ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (06) :1610-1618
[3]   Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries [J].
Briguori, C ;
Tobis, J ;
Nishida, T ;
Vaghetti, M ;
Albiero, R ;
Di Mario, C ;
Colombo, A .
EUROPEAN HEART JOURNAL, 2002, 23 (03) :247-254
[4]   Stent placement to prevent restenosis after angioplasty in small coronary arteries [J].
Doucet, S ;
Schalij, MJ ;
Vrolix, MCM ;
Hilton, D ;
Chenu, P ;
de Bruyne, B ;
Udayachalerm, W ;
Seth, A ;
Bilodeau, L ;
Reiber, JHC ;
Harel, F ;
Lespérance, J .
CIRCULATION, 2001, 104 (17) :2029-2033
[5]   Vessel size and long-term outcome after coronary stent placement [J].
Elezi, S ;
Kastrati, A ;
Neumann, FJ ;
Hadamitzky, M ;
Dirschinger, J ;
Schömig, A .
CIRCULATION, 1998, 98 (18) :1875-1880
[6]   Coronary-artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty [J].
Erbel, R ;
Haude, M ;
Höpp, HW ;
Franzen, D ;
Rupprecht, HJ ;
Heublein, B ;
Fischer, K ;
De Jaegere, P ;
Serruys, P ;
Rutsch, W ;
Probst, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (23) :1672-1678
[7]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[8]   INFLUENCE OF CORONARY VESSEL SIZE ON RENARROWING PROCESS AND LATE ANGIOGRAPHIC OUTCOME AFTER SUCCESSFUL BALLOON ANGIOPLASTY [J].
FOLEY, DP ;
MELKERT, R ;
SERRUYS, PW .
CIRCULATION, 1994, 90 (03) :1239-1251
[9]  
HAUDE M, 2000, AM HEART J, V140, P820
[10]  
Kastrati A, 2000, CATHETER CARDIO INTE, V50, P290, DOI 10.1002/1522-726X(200007)50:3<290::AID-CCD5>3.0.CO