A capillary-based microfluidic instrument suitable for immunoaffinity chromatography

被引:14
作者
Peoples, Michael C.
Phillips, Terry M.
Karnes, H. Thomas
机构
[1] Virginia Commonwealth Univ, Ctr Med, Dept Pharmaceut, Richmond, VA 23298 USA
[2] NIH, Off Res Serv, Div Bioengn & Phys Sci, Ultramicro Analyt Immunochem Resource, Bethesda, MD 20892 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 848卷 / 02期
关键词
microflluidics; immunoglobulins; immunoaffinity; laser induced fluorescence; capillary chromatography;
D O I
10.1016/j.jchromb.2006.10.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of biological samples to produce clinical or research data often requires measurement of analytes from complex biological matrices and limited volumes. Miniaturized analytical systems capable of minimal sample consumption and reduced analysis times have been employed to meet this need. The small footprint of this technology offers the potential for portability and patient point-of-care testing. A prototype microfluidic, system has been developed and is presented for potential rapid assessment of clinical samples. The system has been designed for immunoaffinity chromatography as a means of separating analytes of interest from biological matrices. The instrument is capable of sub-microliter sample injection and detection of labeled antigens by long wavelength laser-induced fluorescence (LIF). The laboratory-constructed device is assembled from an array of components including two syringe pumps, a nano-gradient mixing chip, a micro-injector, a diode laser, and a separation capillary column made from a polymer/silica (PEEKsil) tube. An in-house program written with LabVIEW software controls the syringe pumps to perform step gradient elution and collects the LIF signal as a chromatogram. Initial columns were packed with silica beads to evaluate the system. Optimization of the device has been achieved by measuring flow accuracy with respect to column length and particle size. Syringe size and pressure effects have also been used to characterize the capability of the pumps. Based on test results, a 200-mu m x 25-mm column packed with 1-mu m silica beads was chosen for use with a 500-mu L syringe. The system was tested for mixer proportioning by pumping different compositions of buffer and fluorescent dye solutions in a stepwise fashion. A linear response was achieved for increasing concentrations of fluorescent dye by online mixing (R-2 = 0.9998). The effectiveness of an acidic gradient was confirmed by monitoring pH post-column and measuring premixed solutions offline. Finally, assessment of delectability was achieved by injecting fluorescent dye solutions and measuring the signal from the LIF detector. The limit of detection for the system with these solutions was 10.0 pM or 10.0 amol on-column. As proof-of-principle, immunoaffinity chromatography was demonstrated with immobilized rabbit anti-goat IgG and a fluorescent dye-goat IgG conjugate as a model antigen. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:200 / 207
页数:8
相关论文
共 40 条
[1]   New developments in particle-based immunoassays: Introduction [J].
Bangs, LB .
PURE AND APPLIED CHEMISTRY, 1996, 68 (10) :1873-1879
[2]   Biomolecular recognition on well-characterized beads packed in microfluidic channels [J].
Buranda, T ;
Huang, JM ;
Perez-Luna, VH ;
Schreyer, B ;
Sklar, LA ;
Lopez, GP .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1149-+
[3]   Variable-gradient generator for micro- and nano-HPLC [J].
Cappiello, A ;
Famiglini, G ;
Florucci, C ;
Mangani, F ;
Palma, P ;
Siviero, A .
ANALYTICAL CHEMISTRY, 2003, 75 (05) :1173-1179
[4]   Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay [J].
Cheng, SB ;
Skinner, CD ;
Taylor, J ;
Attiya, S ;
Lee, WE ;
Picelli, G ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1472-1479
[5]  
Chiem NH, 1998, CLIN CHEM, V44, P591
[6]   Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays [J].
Dodge, A ;
Fluri, K ;
Verpoorte, E ;
de Rooij, NF .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3400-3409
[7]   A simplified gradient solvent delivery system for capillary liquid chromatography electrospray ionization mass spectrometry [J].
Ducret, A ;
Bartone, N ;
Haynes, PA ;
Blanchard, A ;
Aebersold, R .
ANALYTICAL BIOCHEMISTRY, 1998, 265 (01) :129-138
[8]   Intraoperative intact parathyroid hormone level monitoring as a guide to parathyroid reimplantation after thyroidectomy [J].
Friedman, M ;
Vidyasagar, R ;
Bliznikas, D ;
Joseph, NJ .
LARYNGOSCOPE, 2005, 115 (01) :34-38
[9]   Immunoaffinity CE for proteomics studies [J].
Guzman, NA ;
Phillips, TM .
ANALYTICAL CHEMISTRY, 2005, 77 (03) :60A-67A
[10]   Improved solid-phase microextraction device for use in on-line immunoaffinity capillary electrophoresis [J].
Guzman, NA .
ELECTROPHORESIS, 2003, 24 (21) :3718-3727