Rapid and simple micromethod for the quantification of fluindione in human plasma using high-performance liquid chromatography

被引:9
作者
Aymard, G [1 ]
Legrand, M [1 ]
Comets, E [1 ]
Mentre, F [1 ]
Diquet, B [1 ]
机构
[1] Assistance Publ Hop Paris, Grp Hosp Pitie Salpetriere, Lab Pharmacocinet, Serv Pharmacol, F-75651 Paris 13, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1998年 / 707卷 / 1-2期
关键词
fluindione;
D O I
10.1016/S0378-4347(97)00587-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new high-performance liquid chromatographic (HPLC) assay without any extraction procedure was developed for the quantification of fluindione in plasma using a 100-mu l sample volume and coumarin as the internal standard. A deproteinization procedure was coupled with a reversed-phase HPLC separation using a 250X4.6 mm I.D. C-18 column and a UV detector set at 280 nm. Peak height ratios were linear over the range 0.05 to 10 mu g/ml (correlation coefficient >0.998). The method was found to be highly reproducible, as indicated by the low value obtained for the coefficient of variation: C.V.less than or equal to 6.1% (n=10). The limit of quantification, estimated under the described conditions at a signal-to-noise ratio of three and with a C.V. lower than 20% for precision and accuracy, was 0.025 mu g/ml. The total turnaround time was 25 min. After storage of blood samples at concentrations of 0.1, 0.5 and 2.5 mu g/ml at room temperature and exposition to light for 120 h, no degradation of fluindione occurred. This micromethod is simple (no extraction step), fast and currently is being used for drug monitoring. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:169 / 173
页数:5
相关论文
共 15 条
  • [1] Andant C, 1997, GASTROEN CLIN BIOL, V21, P237
  • [2] Cazaux V, 1996, THROMB HAEMOSTASIS, V75, P731
  • [3] SIMULTANEOUS DETERMINATION OF 8 ANTICOAGULANT RODENTICIDES IN BLOOD-SERUM AND LIVER
    CHALERMCHAIKIT, T
    FELICE, LJ
    MURPHY, MJ
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (01) : 56 - 61
  • [4] DETERMINATION OF NANOGRAM LEVELS OF THE ANTI-COAGULANT ACENOCOUMARIN IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEWOLFF, FA
    TETTEROOTEMPELMAN, CAM
    EDELBROEK, PM
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1980, 4 (03) : 156 - 159
  • [5] RAPID AND SENSITIVE DETERMINATION OF COUMARIN AND 7-HYDROXYCOUMARIN AND ITS GLUCURONIDE CONJUGATE IN URINE AND PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    EGAN, DA
    OKENNEDY, R
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 582 (1-2): : 137 - 143
  • [6] BIOCHEMICAL APPLICATIONS OF A QUANTITATIVE HIGH-PRESSURE LIQUID-CHROMATOGRAPHIC ASSAY OF WARFARIN AND ITS METABOLITES
    FASCO, MJ
    PIPER, LJ
    KAMINSKY, LS
    [J]. JOURNAL OF CHROMATOGRAPHY, 1977, 131 (JAN21): : 365 - 373
  • [7] Fluindione induced fever
    Grunenberger, F
    Thiry, L
    Sader, N
    Schlienger, JL
    Imler, M
    [J]. REVUE DE MEDECINE INTERNE, 1995, 16 (12): : 973 - 974
  • [8] A METHOD FOR THE SIMULTANEOUS IDENTIFICATION AND QUANTITATION OF 5 SUPERWARFARIN RODENTICIDES IN HUMAN SERUM
    KUIJPERS, EAP
    DENHARTIGH, J
    SAVELKOUL, TJF
    DEWOLFF, FA
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (07) : 557 - 562
  • [9] SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF COUMARIN IN PLASMA
    LAMIABLE, D
    VISTELLE, R
    TRENQUE, T
    FAY, R
    MILLART, H
    CHOISY, H
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 620 (02): : 273 - 277
  • [10] LEFLOCH E, 1995, PRESSE MED, V24, P828