Ultrasound-Assisted Emulsification Microextraction for Determination of 2,4,6-Trichloroanisole in Wine Samples by Gas Chromatography Tandem Mass Spectrometry

被引:41
作者
Fontana, Ariel R. [1 ]
Patil, Sangram H. [2 ]
Banerjee, Kaushik [2 ]
Altamirano, Jorgelina C. [1 ,3 ]
机构
[1] Consejo Nacl Invest Cient & Tecn, CCT, LISAMEN, Grp Invest & Desarrollo Quim Analit QUIANID, RA-5500 Mendoza, Argentina
[2] Natl Res Ctr Grapes, Pune 412307, Maharashtra, India
[3] Univ Nacl Cuyo, Inst Ciencias Basicas, Dept Quim, RA-5500 Mendoza, Argentina
关键词
Wine; cork taint; 2,4,6-trichloroanisole; ultrasound-assisted emulsification-microextraction; wine analysis; gas chromatography-mass spectrometry; SOLID-PHASE MICROEXTRACTION; SINGLE-DROP MICROEXTRACTION; ELECTRON-CAPTURE DETECTION; BAR SORPTIVE EXTRACTION; CORK TAINT; WATER SAMPLES; CHLOROANISOLES; OPTIMIZATION; PESTICIDES;
D O I
10.1021/jf904396g
中图分类号
S [农业科学];
学科分类号
082806 [农业信息与电气工程];
摘要
A fast and effective microextraction technique is proposed for preconcentration of 2,4,6-trichloroanisole (2,4,6-TCA) from wine samples prior gas chromatography tandem mass spectrometric (GC-MS/MS) analysis. The proposed technique is based on ultrasonication (US) for favoring the emulsification phenomenon during the extraction stage. Several variables influencing the relative response of the target analyte were studied and optimized. Under optimal experimental conditions, 2,4,6-TCA was quantitatively extracted achieving enhancement factors (EF) >= 400 and limits of detection (LODs) 0.6-0.7 ng L-1 with relative standard deviations (RSDs) <= 11.3%, when 10 ng L-1 2,4,6-TCA standard-wine sample blend was analyzed. The calibration graphs for white and red wine were linear within the range of 5-1000 ng L-1, and estimation coefficients (r(2)) were >= 0.9995. Validation of the methodology was carried out by standard addition method at two concentrations (10 and 50 ng L-1) achieving recoveries >80% indicating satisfactory robustness of the method. The methodology was successfully applied for determination of 2,4,6-TCA in different wine samples.
引用
收藏
页码:4576 / 4581
页数:6
相关论文
共 27 条
[1]
Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]
Accurate determination of 2,4,6-trichloroanisole in wines at low parts per trillion by solid-phase microextraction followed by GC-ECD [J].
Alzaga, R ;
Ortiz, L ;
Sáchez-Baeza, F ;
Marco, MP ;
Bayona, JM .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (12) :3509-3514
[3]
Rapid headspace solid-phase microextraction/gas chromatographic/mass spectrometric assay for the quantitative determination of some of the main odorants causing off-flavours in wine [J].
Boutou, Stephane ;
Chatonnet, Pascal .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1141 (01) :1-9
[4]
IDENTIFICATION OF 2,4,6-TRICHLOROANISOLE AS A POTENT COMPOUND CAUSING CORK TAINT IN WINE [J].
BUSER, HR ;
ZANIER, C ;
TANNER, H .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1982, 30 (02) :359-362
[5]
Purge-and-trap preconcentration system coupled to capillary gas chromatography with atomic emission detection for 2,4,6-trichloroanisole determination in cork stoppers and wines [J].
Campillo, N ;
Aguinaga, N ;
Viñas, P ;
López-García, I ;
Hernández-Córdoba, M .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (01) :85-91
[6]
Ultrasound-assisted preparation of liquid samples [J].
de Castro, M. D. Luque ;
Priego-Capote, F. .
TALANTA, 2007, 72 (02) :321-334
[7]
DeCastro MDL, 2007, TECH INSTRUMENT, V26, P1
[8]
Determination of volatile phenols in fino sherry wines [J].
Domínguez, C ;
Guillén, DA ;
Barroso, CG .
ANALYTICA CHIMICA ACTA, 2002, 458 (01) :95-102
[9]
Analysis of 2,4,6-trichloroanisole in wines using solid-phase microextraction coupled to gas chromatography mass spectrometry [J].
Evans, TJ ;
Butzke, CE ;
Ebeler, SE .
JOURNAL OF CHROMATOGRAPHY A, 1997, 786 (02) :293-298
[10]
Simple approach based on ultrasound-assisted emulsification-microextraction for determination of polibrominated flame retardants in water samples by gas chromatography-mass spectrometry [J].
Fontana, Ariel R. ;
Wuilloud, RodolfoG. ;
Martinez, Luis D. ;
Altamirano, Jorgelina C. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (01) :147-153