In vitro human scleral permeability of fluorescein, dexamethasone-fluorescein, methotrexate-fluorescein and rhodamine 6G and the use of a coated coil as a new drug delivery system

被引:60
作者
Cruysberg, LPJ
Nuijts, RMMA
Geroski, DH
Koole, LH
Hendrikse, F
Edelhauser, HF
机构
[1] Emory Univ, Dept Ophthalmol, Atlanta, GA 30322 USA
[2] Univ Hosp, Dept Ophthalmol, Maastricht, Netherlands
[3] Univ Hosp, Ctr Biomat, Maastricht, Netherlands
关键词
D O I
10.1089/108076802321021108
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To determine the in vitro human scleral permeability of several dyes and drug-dye combinations with varying molecular weights (MW) and lipid solubilities (fluorescein, dexamethasone-fluorescein, methotrexate-fluorescein, and rhodamine). Coils coated with rhodamine were also evaluated for scleral permeability and sustained release. Methods Scleral sections excised from moist chamber stored human globes were mounted in a 2-compartment perfusion chamber. A small depot of drug/dye (100 mul of 10(-4) M fluorescein, dexamethasone-fluorescein, methotrexate-fluorescein or rhodamine) or a coated coil in 100 mul of BSS was added to the episcleral surface while perfusing BSS to the choroidal side. The perfusate was collected and measured for fluorescence. Permeability was calculated as K-trans from the flux measurements. Results K-trans values (cm/sec, mean +/- SE) for the studied dyes and drug-dye combinations were 5.21 +/- 0.71 x 10(-6) for fluorescein, 1.64 +/- 0.17 x 10(-6) for dexamethasone-fluorescein, 3.36 +/- 0.62 x 10(-6) for methotrexate-fluorescein, 1.86 +/- 0.39 x 10(-6) for rhodamine and 2.18 +/- 0.23 x 10(-6) for the rhodamine from the coils. We found a significant difference between the permeability of the sclera to fluorescein and dexamethasone-fluorescein (P < 0.001), methotrexate-fluorescein (P < 0.05) and rhodamine (P < 0.001). Steady state flux was observed from the rhodamine coil. Conclusion The rank order of scleral permeability to the studied dyes is as follows: fluorescein > methotrexate-fluorescein > rhodamine coil > rhodamine 6G > dexamethasone-fluorescein. Differences in scleral permeability are related to MW and lipid solubility. Prolonged transscleral diffusion of rhodamine delivered by solution and by coil are similar.
引用
收藏
页码:559 / 569
页数:11
相关论文
共 23 条
[1]  
Ambati J, 2000, INVEST OPHTH VIS SCI, V41, P1181
[2]  
Ambati J, 2000, INVEST OPHTH VIS SCI, V41, P1186
[3]   INTRAOCULAR PENETRATION OF GENTAMICIN AFTER SUB-CONJUNCTIVAL AND RETROBULBAR INJECTION [J].
BARZA, M ;
KANE, A ;
BAUM, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1978, 85 (04) :541-547
[4]  
COOPER E R, 1987, Journal of Controlled Release, V6, P23, DOI 10.1016/0168-3659(87)90061-7
[5]   Fiber matrix model of sclera and corneal stroma for drug delivery to the eye [J].
Edwards, A ;
Prausnitz, MR .
AICHE JOURNAL, 1998, 44 (01) :214-225
[6]  
Foster CS, 1994, SCLERA, P1
[7]  
Geroski DH, 2000, INVEST OPHTH VIS SCI, V41, P961
[8]  
Hamalainen KM, 1997, INVEST OPHTH VIS SCI, V38, P627
[9]  
Hanssen HHL, 1999, J BIOMED MATER RES, V48, P820, DOI 10.1002/(SICI)1097-4636(1999)48:6<820::AID-JBM9>3.0.CO
[10]  
2-K