Determination of drugs in biological fluids by high-performance liquid chromatography with on-line sample processing

被引:49
作者
Oertel, R [1 ]
Richter, K [1 ]
Gramatté, T [1 ]
Kirch, W [1 ]
机构
[1] Tech Univ Dresden, Med Fac Carl Gustav Carus, Inst Clin Pharmacol, D-01307 Dresden, Germany
关键词
sample handling; column switching; drugs;
D O I
10.1016/S0021-9673(97)00966-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated two column HPLC system with the new packing material LiChrospher RP-18 ADS (alkyl-diol-silica) was tested for the determination of several drugs and metabolites (talinolol, celiprolol, metoprolol, oxprenolol, triamterene, trimethoprim, tiracizine, artcaine, detajmium, ajmaline, lamotrigine) in various biological fluids (serum, urine, intestinal aspirates, supernatants of cell cultures and supernatants after protein denaturation). The method allows the direct injection of biological fluids into a reversed-phase HPLC system and on-line clean-up and sample enrichment by a column-switching technique. Precision, accuracy and sensitivity were similar to conventional assays as described in the literature. With this new method it was possible to measure drug concentrations in various biological fluids without changing the sample preparation procedure. In some cases an additional sample preparation like protein denaturation or solid-phase extraction was advantageous to enhance the sensitivity of the method and the life-time of the ADS column. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:203 / 209
页数:7
相关论文
共 21 条
  • [1] ANDERSON DJ, 1993, ANAL CHEM, V65, P434
  • [2] DOSE-DEPENDENT TIRACIZINE DISPOSITION IN HEALTHY-VOLUNTEERS - SERUM AND URINE KINETICS AND DOSE-RELATED ECG-CHANGES
    BERNDT, A
    GRAMATTE, T
    OERTEL, R
    RICHTER, K
    TERHAAG, B
    KIRCH, W
    [J]. EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 1994, 19 (04) : 359 - 368
  • [3] Berndt Annette, 1994, Am J Ther, V1, P22, DOI 10.1097/00045391-199406000-00005
  • [4] ALKYL-DIOL SILICA (ADS) - RESTRICTED ACCESS PRECOLUMN PACKINGS FOR DIRECT-INJECTION AND COUPLED-COLUMN CHROMATOGRAPHY OF BIOFLUIDS
    BOOS, KS
    RUDOLPHI, A
    VIELHAUER, S
    WALFORT, A
    LUBDA, D
    EISENBEISS, F
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8): : 684 - 690
  • [5] COLUMN-SWITCHING TECHNIQUES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DRUGS IN BIOLOGICAL SAMPLES
    CAMPINSFALCO, P
    HERRAEZHERNANDEZ, R
    SEVILLANOCABEZA, A
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (02): : 177 - 190
  • [6] Validated assay for the determination of celiprolol in plasma using high-performance liquid chromatography and a silanol deactivated reversed-phase support
    Chiu, FCK
    Raymond, K
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (02): : 462 - 465
  • [7] PERFORMANCE ANALYSIS OF A REVERSED-PHASE LIQUID-CHROMATOGRAPHIC ASSAY OF LAMOTRIGINE IN PLASMA USING SOLVENT-DEMIXING EXTRACTION
    COCIGLIO, M
    ALRIC, R
    BOUVIER, O
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 572 (1-2): : 269 - 276
  • [8] FREY HO, 1994, GIT LABOR MED, V17, P166
  • [9] Direct demonstration of small intestinal secretion and site-dependent absorption of the beta-blocker talinolol in humans
    Gramatte, T
    Oertel, R
    Terhaag, B
    Kirch, W
    [J]. CLINICAL PHARMACOLOGY & THERAPEUTICS, 1996, 59 (05) : 541 - 549
  • [10] PARACETAMOL ABSORPTION FROM DIFFERENT SITES IN THE HUMAN SMALL-INTESTINE
    GRAMATTE, T
    RICHTER, K
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1994, 37 (06) : 608 - 611