Entrapment of pulmonary artery catheter in a suture at the inferior vena cava cannulation site

被引:20
作者
Huang, L
Elsharydah, A
Nawabi, A
Cork, RC
机构
[1] Louisiana State Univ, Ctr Hlth Sci, Dept Anesthesiol, Shreveport, LA 71130 USA
[2] Louisiana State Univ, Ctr Hlth Sci, Dept Surg, Shreveport, LA 71130 USA
关键词
catheterization; complications; entrapment; pulmonary artery catheter; Swan-Ganz catheter;
D O I
10.1016/j.jclinane.2004.02.003
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Entrapment of a pulmonary artery catheter (Swan-Ganz catheter) in the heart, vena cava, or pulmonary artery is a very rare and serious complication that may lead to life-threatening complications such as cardiac rupture, pulmonary artery rupture, cardiac tamponade, among others, if not recognized and treated early. We report entrapment of a Swan-Ganz catheter in the purse-string suture at the inferior vena cava cannulation site for a patient undergoing aortic valve replacement. This situation required a repeat sternotomy to release the pulmonary artery catheter. (C) 2004 by Elsevier Inc.
引用
收藏
页码:557 / 559
页数:3
相关论文
共 11 条
[1]  
BLOCK PC, 1976, J THORAC CARDIOV SUR, V71, P917
[2]  
De Hert S G, 1993, Acta Anaesthesiol Belg, V44, P53
[3]   Catheter entrapment by atrial suture during minimally invasive port-access cardiac surgery [J].
Deneu, S ;
Coddens, J ;
Deloof, T .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (10) :983-986
[4]   Early recognition of pulmonary artery catheter entrapment with TEE [J].
Dubois, PE ;
Collard, E ;
Xenitos, P ;
Louagie, YAG .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (01) :142-143
[5]   Pulmonary artery rupture after attempted removal of a pulmonary artery catheter [J].
Huang, GS ;
Wang, HJ ;
Chen, CH ;
Ho, ST ;
Wong, CS .
ANESTHESIA AND ANALGESIA, 2002, 95 (02) :299-301
[6]   Swan-Ganz catheter entrapment in open heart surgery [J].
Kaplan, M ;
Demirtas, M ;
Çimen, S ;
Kut, MS ;
Özay, B ;
Kanca, A ;
Özler, A .
JOURNAL OF CARDIAC SURGERY, 2000, 15 (05) :313-315
[7]   INADVERTENT INTRACARDIAC ENTRAPMENT OF A SWAN-GANZ CATHETER [J].
KLOCKGETHERRADKE, A ;
RATHGEBER, J ;
LANGE, H .
ANAESTHESIST, 1995, 44 (02) :116-118
[8]   VENTRICULAR ENTRAPMENT OF A SWAN-GANZ CATHETER - A TECHNIQUE FOR NONSURGICAL REMOVAL [J].
LAZZAM, C ;
SANBORN, TA ;
CHRISTIAN, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1422-1424
[9]   INADVERTENT SUTURE FIXATION OF A SWAN-GANZ CATHETER TO THE PULMONARY-ARTERY DURING CARDIAC-SURGERY [J].
PFEIFFER, K ;
WIDMANN, M ;
DEUSCH, H ;
GUGGENBERGER, H ;
DUDA, S ;
SEBOLDT, H .
ANAESTHESIST, 1995, 44 (11) :782-784
[10]   SUCCESSFUL NONSURGICAL EXTRACTION OF A KNOTTED PULMONARY-ARTERY CATHETER TRAPPED IN THE RIGHT VENTRICLE [J].
TREMBLAY, N ;
TAILLEFER, J ;
HARDY, JF .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (03) :293-295