Optimization of a GFAAS method for determination of total inorganic arsenic in drinking water

被引:42
作者
Michon, Jerome [1 ]
Deluchat, Veronique [1 ]
Al Shukry, Raad [1 ]
Dagot, Christophe [1 ]
Bollinger, Jean-Claude [1 ]
机构
[1] Fac Sci & Tech, Lab Sci Eau & Environm, FR-87060 Limoges, France
关键词
graphite furnace atomic absorption spectrometry (GFAAS); UltrAA-Lamp((R)); trace inorganic arsenic determination; drinking water; data processing software;
D O I
10.1016/j.talanta.2006.06.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The new 10 mu g l(-1) arsenic standard in drinking water has been a spur to the search for reliable routine analytical methods with a limit of detection at the mu g l(-1) level. These methods also need to be easy to handle due to the routine analyses that are required in drinking water monitoring. Graphite furnace atomic absorption spectrometry (GFAAS) meets these requirements, but the limit of detection is generally too high except for methods using a pre-concentration or separation step. The use of a high-intensity boosted discharge hollow-cathode lamp decreases the baseline noise level and therefore allows a lower limit of detection. The temperature program, chemical matrix modifier and thermal stabilizer additives were optimized for total inorganic arsenic determination with GFAAS, without preliminary treatment. The optimal furnace program was validated with a proprietary software. The limit of detection was 0.26 mu g As l(-1) for a sample volume of 16 mu l corresponding to 4.2 pg As. This attractive technique is rapid as 20 samples can be analysed per hour. This method was validated with arsenic reference solutions. Its applicability was verified with artificial and natural groundwaters. Recoveries from 91 to 105% with relative standard deviation < 5% can be easily achieved. The effect of interfering anions and cations commonly found in groundwater was studied. Only phosphates and silicates (respectively at 4 and 20 mg l(-1)) lead to significant interferences in the determination of total inorganic arsenic at 4 mu g l(-1). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:479 / 485
页数:7
相关论文
共 28 条
[1]   DETERMINATION OF ARSENIC(III) AND TOTAL ARSENIC BY ATOMIC-ABSORPTION SPECTROSCOPY [J].
AGGETT, J ;
ASPELL, AC .
ANALYST, 1976, 101 (1202) :341-347
[2]   Speciation of arsenic in ground water samples: A comparative study of CE-UV HG-AAS and LC-ICP-MS [J].
Akter, KF ;
Chen, Z ;
Smith, L ;
Davey, D ;
Naidu, R .
TALANTA, 2005, 68 (02) :406-415
[3]   Determination of arsenic(III) and total arsenic(III,V) in water samples by resin suspension graphite furnace atomic absorption spectrometry [J].
Anezaki, K ;
Nukatsuka, I ;
Ohzeki, K .
ANALYTICAL SCIENCES, 1999, 15 (09) :829-834
[4]  
[Anonymous], 1998, OFF J, V330, P32
[5]   Analytical performance of arsenic and selenium boasted hollow cathode lamps [J].
Bezur, L .
MICROCHEMICAL JOURNAL, 1998, 59 (01) :107-116
[6]   Analytical methodology for speciation of arsenic in environmental and biological samples [J].
Burguera, M ;
Burguera, JL .
TALANTA, 1997, 44 (09) :1581-1604
[7]   Determination of As(III) and total inorganic arsenic by flow injection hydride generation atomic absorption spectrometry [J].
Coelho, NMM ;
da Silva, AC ;
da Silva, CM .
ANALYTICA CHIMICA ACTA, 2002, 460 (02) :227-233
[8]   Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995) [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :105-126
[9]  
FILHO VRA, 2002, ATOM SPECTROSC, V23, P7
[10]   Determination of arsenic species: A critical review of methods and applications, 2000-2003 [J].
Francesconi, KA ;
Kuehnelt, D .
ANALYST, 2004, 129 (05) :373-395