Multiplexed particle-based flow cytometric assays

被引:747
作者
Vignali, DAA [1 ]
机构
[1] St Jude Childrens Res Hosp, Dept Immunol, Memphis, TN 38105 USA
关键词
cytokines; ELISA; flow cytometry; FlowMetrix (TM); microspheres; quantitation;
D O I
10.1016/S0022-1759(00)00238-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several methods have been developed to quantify soluble analytes in biological fluids and tissue culture samples, including bioassays, ELISA, RPA and PCR. However, each of these techniques possesses one or more significant limitations; ELISA will only measure one analyte as a time; PCR does not detect native protein. The recent development of particle-based flow cytometric assays has raised hopes that many of these limitations can be overcome. The technology utilizes microspheres as the solid support for a conventional immunoassay, affinity assay or DNA hybridization assay which are subsequently analyzed on a flow cytometer. Several multiplexed bead systems are currently marketed by different vendors, We have used the Luminex FlowMetrix(TM) system which consists of 64 different bead sets manufactured with uniform, distinct proportions of red and orange fluorescent dyes (detected by FL2/FL3 on a FACScan). Each bead set forms the basis of an individual assay using a green fluorescent reporter dye (FL1). This system facilitates the development of multiplexed assays that simultaneously measure many different analytes in a small sample volume. They can also be developed into rapid, 'no wash' assays that can be completed in <2 h. This review traces the historical association between microspheres and flow cytometry, the development and use of particle-based flow cytometric assays, how they compare with current assays and potential future developments of this very exciting technology. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:243 / 255
页数:13
相关论文
共 59 条
  • [1] MONOCLONAL-ANTIBODY 2-SITE ELISA FOR HUMAN IFN-GAMMA - ADAPTATION FOR DETERMINATIONS IN HUMAN-SERUM OR PLASMA
    ANDERSSON, G
    EKRE, HPT
    ALM, G
    PERLMANN, P
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 125 (1-2) : 89 - 96
  • [2] Natural antibodies to IL-2
    Balsari, A
    Caruso, A
    [J]. BIOTHERAPY, 1997, 10 (01) : 25 - 28
  • [3] Benecky MJ, 1997, CLIN CHEM, V43, P1764
  • [4] Benecky MJ, 1998, CLIN CHEM, V44, P2052
  • [5] SEROLOGICAL DETECTION OF HELICOBACTER-PYLORI BY A FLOW MICROSPHERE IMMUNOFLUORESCENCE ASSAY
    BEST, LM
    VANZANTEN, SJOV
    BEZANSON, GS
    HALDANE, DJM
    MALATJALIAN, DA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (09) : 2311 - 2317
  • [6] BODNER A, 1996, ABSTR GEN M AM SOC M, P288
  • [7] BOSCATO LM, 1988, CLIN CHEM, V34, P27
  • [8] FLOW CYTOMETRIC DETECTION AND QUANTITATION OF THE EPIDERMAL GROWTH-FACTOR RECEPTOR IN COMPARISON TO SCATCHARD ANALYSIS IN HUMAN BLADDER-CARCINOMA CELL-LINES
    BROCKHOFF, G
    HOFSTAEDTER, F
    KNUECHEL, R
    [J]. CYTOMETRY, 1994, 17 (01): : 75 - 83
  • [9] SINGLE-CELL ANALYSIS OF CYTOKINE GENE COEXPRESSION DURING CD4(+) T-CELL PHENOTYPE DEVELOPMENT
    BUCY, RP
    KARR, L
    HUANG, GQ
    LI, JM
    CARTER, D
    HONJO, K
    LEMONS, JA
    MURPHY, KM
    WEAVER, CT
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (16) : 7565 - 7569
  • [10] Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay
    Carson, RT
    Vignali, DAA
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) : 41 - 52