On the use of graphical method to determine the targets of single-contaminant regeneration recycling water systems

被引:115
作者
Feng, Xiao [1 ]
Bai, Jie [1 ]
Zheng, Xuesong [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Chem Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
integration; regeneration recycling; graphical method; target; water system;
D O I
10.1016/j.ces.2006.12.081
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Water system integration with regeneration recycling can reduce freshwater consumption and wastewater discharge to the maximum extent. In this paper, by analyzing the limiting composite curve of a single-contaminant water system, a method is proposed to construct the optimal water supply line for regeneration recycling. Accordingly the targets for regeneration recycling water systems are obtained. The targets in sequence are the minimum freshwater consumption (the minimum wastewater discharge), the minimum regenerated water flowrate, and the optimal regeneration concentration. The post-regeneration concentration is taken to be fixed in the sequential targeting procedure. The interactions of these targets are analyzed, and formulas for calculating these targets are proposed. The results show that for a single-contaminant regeneration recycling water system, the minimum freshwater consumption is determined by the shape of the limiting composite curve below the post-regeneration concentration. The optimal regeneration concentration is defined as the minimum regeneration concentration at the minimum freshwater consumption and the corresponding minimum regenerated water flowrate. The minimum regenerated water flowrate and the optimal regeneration concentration are both related to the geometrical features of the limiting composite curve of the water-using system and to the post-regeneration concentration. The optimal regeneration concentration has no direct relationship with the pinch concentration. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2127 / 2138
页数:12
相关论文
共 19 条
[1]   On the use of linear models for the design of water utilization systems in process plants with a single contaminant [J].
Bagajewicz, M ;
Savelski, M .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2001, 79 (A5) :600-610
[2]   A review of recent design procedures for water networks in refineries and process plants [J].
Bagajewicz, M .
COMPUTERS & CHEMICAL ENGINEERING, 2000, 24 (9-10) :2093-2113
[3]  
CAO D, 2004, CHEM ENGN RES DESIGN, V82
[4]   Optimized design of wastewater treatment systems: Application to the mechanical pulp and paper industry .1. Design and cost relationships [J].
Fels, M ;
Pinter, J ;
Lycon, DS .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1997, 75 (02) :437-451
[5]   Cost optimization of industrial wastewater reuse systems [J].
Feng, X ;
Chu, KH .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2004, 82 (B3) :249-255
[6]   Automated design of total water systems [J].
Gunaratnam, M ;
Alva-Argáez, A ;
Kokossis, A ;
Kim, JK ;
Smith, R .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (03) :588-599
[7]   A new graphical targeting method for water minimisation [J].
Hallale, N .
ADVANCES IN ENVIRONMENTAL RESEARCH, 2002, 6 (03) :377-390
[8]   A mathematical programming model for water usage and treatment network design [J].
Huang, CH ;
Chang, CT ;
Ling, HC ;
Chang, CC .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1999, 38 (07) :2666-2679
[9]   On zero water discharge solutions in the process industry [J].
Koppol, AR ;
Bagajewicz, MJ ;
Dericks, BJ ;
Savelski, MJ .
ADVANCES IN ENVIRONMENTAL RESEARCH, 2004, 8 (02) :151-171
[10]   Designing for the interactions between water-use and effluent treatment [J].
Kuo, WCJ ;
Smith, R .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 1998, 76 (A3) :287-301