Automated model-based organ delineation for radiotherapy planning in prostatic region

被引:130
作者
Pekar, V
McNutt, TR
Kaus, MR
机构
[1] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
[2] Philips Med Syst, Madison, WI USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 60卷 / 03期
关键词
radiotherapy planning; organ delineation; deformable organ models; organ-specific features; model adaptation by energy minimization;
D O I
10.1016/j.ijrobp.2004.06.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Organ delineation is one of the most tedious and time-consuming parts of radiotherapy planning. It is usually performed by manual contouring in two-dimensional slices using simple drawing tools, and it may take several hours to delineate all structures of interest in a three-dimensional (3D) data set used for planning. In this paper, a 3D model-based approach to automated organ delineation is introduced that allows for a significant reduction of the time required for contouring. Methods and Materials: The presented method is based on an adaptation of 3D deformable surface models to the boundaries of the anatomic structures of interest. The adaptation is based on a tradeoff between deformations of the model induced by its attraction to certain image features and the shape integrity of the model. To make the concept clinically feasible, interactive tools are introduced that allow quick correction in problematic areas in which the automated model adaptation may fail. A feasibility study with 40 clinical data sets was done for the nude pelvic area, in which the risk organs (bladder, rectum, and femoral heads) were segmented by automatically adapting the corresponding organ models. Results: In several cases of the validation study, minor user interaction was required. Nevertheless, a statistically significant reduction in the time required compared with manual organ contouring was achieved. The results of the validation study showed that the presented model-based approach is accurate (1.0-1.7 mm mean error) for the tested anatomic structures. Conclusion: A framework for organ delineation in radiotherapy planning is presented, including automated 3D model-based segmentation, as well as tools for interactive corrections. We demonstrated that the proposed approach is significantly more efficient than manual contouring in two-dimensional slices. (C) 2004 Elsevier Inc.
引用
收藏
页码:973 / 980
页数:8
相关论文
共 21 条
[1]   IMAGE SELECTIVE SMOOTHING AND EDGE-DETECTION BY NONLINEAR DIFFUSION .2. [J].
ALVAREZ, L ;
LIONS, PL ;
MOREL, JM .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1992, 29 (03) :845-866
[2]  
[Anonymous], LECT NOTES COMPUTER
[3]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[4]  
BUENO G, 2001, P MED IM UND AN MIUA, P73
[5]  
COLLINS DL, 1992, P SOC PHOTO-OPT INS, V1808, P10, DOI 10.1117/12.131063
[6]   USE OF ACTIVE SHAPE MODELS FOR LOCATING STRUCTURE IN MEDICAL IMAGES [J].
COOTES, TF ;
HILL, A ;
TAYLOR, CJ ;
HASLAM, J .
IMAGE AND VISION COMPUTING, 1994, 12 (06) :355-365
[7]   Automatic segmentation of brain structures for radiation therapy planning [J].
D'Haese, PF ;
Duay, V ;
Li, R ;
d'Aische, ADB ;
Merchant, TE ;
Cmelak, AJ ;
Donnelly, EF ;
Niermann, KJ ;
Macq, B ;
Dawant, BM .
MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 :517-526
[8]   Sectored snakes: Evaluating learned-energy segmentations [J].
Fenster, SD ;
Kender, JR .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2001, 23 (09) :1028-1034
[9]   PROCRUSTES METHODS IN THE STATISTICAL-ANALYSIS OF SHAPE [J].
GOODALL, C .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1991, 53 (02) :285-339
[10]   METHODS OF CONJUGATE GRADIENTS FOR SOLVING LINEAR SYSTEMS [J].
HESTENES, MR ;
STIEFEL, E .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1952, 49 (06) :409-436