Comparison of the Eragen Multi-Code Respiratory Virus Panel with Conventional Viral Testing and Real-Time Multiplex PCR Assays for Detection of Respiratory Viruses

被引:30
作者
Arens, Max Q. [1 ]
Buller, Richard S. [1 ]
Rankin, Anne [1 ]
Mason, Sheila [1 ]
Whetsell, Amy [1 ]
Agapov, Eugene [2 ]
Lee, Wai-Ming [3 ]
Storch, Gregory A. [1 ,2 ]
机构
[1] Washington Univ, Dept Pediat, Sch Med, St Louis, MO 63110 USA
[2] Washington Univ, Dept Med, Sch Med, St Louis, MO 63110 USA
[3] Univ Wisconsin, Dept Pediat, Sch Med & Publ Hlth, Madison, WI USA
基金
美国国家卫生研究院;
关键词
ACID AMPLIFICATION TESTS; HUMAN RHINOVIRUSES; YOUNG-CHILDREN; TRACT SAMPLES; IDENTIFICATION; CORONAVIRUS; INFECTION; PATHOGENS; DIAGNOSIS; GENOTYPE;
D O I
10.1128/JCM.00220-10
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
High-throughput multiplex assays for respiratory viruses are an important step forward in diagnostic virology. We compared one such assay, the PLx Multi-Code Respiratory Virus Panel (PLx-RVP), manufactured by Eragen Biosciences, Inc. (Madison, WI), with conventional virologic testing, consisting of fluorescent-antibody staining plus testing with the R-mix system and fibroblast tube cultures. The test set consisted of 410 archived respiratory specimens, mostly nasopharyngeal swabs, including 210 that had been positive by conventional testing for a balanced selection of common respiratory viruses. Specimens yielding discrepant results were evaluated using a panel of respiratory virus PCR assays developed, characterized, and validated with clinical specimens. PLx-RVP increased the total rate of detection of viruses by 35.8%, and there was a 25.7% increase in the rate of detection of positive specimens. Reference PCR assay results corroborated the PLx-RVP result for 54 (82%) of 66 discrepancies with conventional testing. Of the 12 specimens with discrepancies between PLx-RVp and the reference PCRs, 6 were positive for rhinovirus by PLx-RVP and the presence of rhinovirus was confirmed by nucleotide sequencing. The remaining six specimens included five in which the PLx-RVP failed to detect parainfluenza virus and one in which the detection of influenza A virus by PLx-RVP could not be confirmed by the reference PCR. Taking the results of the reference PCR assay results into account, the sensitivities of the PLx-RVP for individual viruses ranged from 94 to 100% and the specificities ranged from 99 to 100%. We conclude that PLx-RVP is a highly accurate system for the detection of respiratory viruses and significantly improves the rate of detection of these viruses compared to that by conventional virologic testing.
引用
收藏
页码:2387 / 2395
页数:9
相关论文
共 23 条
[1]   Genetic variability of human metapneumovirus infection: Evidence of a shift in viral genotype without a change in illness [J].
Agapov, E ;
Sumino, KC ;
Gaudreault-Keener, M ;
Storch, GA ;
Holtzman, MJ .
JOURNAL OF INFECTIOUS DISEASES, 2006, 193 (03) :396-403
[2]   Cloning of a human parvovirus by molecular screening of respiratory tract samples [J].
Allander, T ;
Tammi, MT ;
Eriksson, M ;
Bjerkner, A ;
Tiveljung-Lindell, A ;
Andersson, B .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (36) :12891-12896
[3]   Identification of a third human polyomavirus [J].
Allander, Tobias ;
Andreasson, Kalle ;
Gupta, Shawon ;
Bjerkner, Annelie ;
Bogdanovic, Gordana ;
Persson, Mats A. A. ;
Dalianis, Tina ;
Ramqvist, Torbjorn ;
Andersson, Bjorn .
JOURNAL OF VIROLOGY, 2007, 81 (08) :4130-4136
[4]   A previously undescribed coronavirus associated with respiratory disease in humans [J].
Fouchier, RAM ;
Hartwig, NG ;
Bestebroer, TM ;
Niemeyer, B ;
de Jong, JC ;
Simon, JH ;
Osterhaus, ADME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (16) :6212-6216
[5]   Identification of a novel polyomavirus from patients with acute respiratory tract infections [J].
Gaynor, Anne M. ;
Nissen, Michael D. ;
Whiley, David M. ;
Mackay, Ian M. ;
Lambert, Stephen B. ;
Wu, Guang ;
Brennan, Daniel C. ;
Storch, Gregory A. ;
Sloots, Theo P. ;
Wang, David .
PLOS PATHOGENS, 2007, 3 (05) :595-604
[6]   Genotype prevalence and risk factors for severe clinical adenovirus infection, united states 2004-2006 [J].
Gray, Gregory C. ;
McCarthy, Troy ;
Lebeck, Mark G. ;
Schnurr, David P. ;
Russell, Kevin L. ;
Kajon, Adriana E. ;
Landry, Marie L. ;
Leland, Diane S. ;
Storch, Gregory A. ;
Ginocchio, Christine C. ;
Robinson, Christine C. ;
Demmler, Gail J. ;
Saubolle, Michael A. ;
Kehl, Sue C. ;
Selvarangan, Rangaraj ;
Miller, Melissa B. ;
Chappell, James D. ;
Zerr, Danielle M. ;
Kiska, Deanna L. ;
Halstead, Diane C. ;
Capuano, Ana W. ;
Setterquist, Sharon F. ;
Chorazy, Margaret L. ;
Dawson, Jeffrey D. ;
Erdman, Dean D. .
CLINICAL INFECTIOUS DISEASES, 2007, 45 (09) :1120-1131
[7]   Multiplexed genetic analysis using an expanded genetic alphabet [J].
Johnson, SC ;
Marshall, DJ ;
Harms, G ;
Miller, CM ;
Sherrill, CB ;
Beaty, EL ;
Lederer, SA ;
Roesch, EB ;
Madsen, G ;
Hoffman, GL ;
Laessig, RH ;
Kopish, GJ ;
Baker, MW ;
Benner, SA ;
Farrell, PM ;
Prudent, JR .
CLINICAL CHEMISTRY, 2004, 50 (11) :2019-2027
[8]   Enhanced identification of viral and atypical bacterial pathogens in lower respiratory tract samples with nucleic acid amplification tests [J].
Lee, BE ;
Robinson, JL ;
Khurana, V ;
Pang, XLL ;
Preiksaitis, JK ;
Fox, JD .
JOURNAL OF MEDICAL VIROLOGY, 2006, 78 (05) :702-710
[9]   A Diverse Group of Previously Unrecognized Human Rhinoviruses Are Common Causes of Respiratory Illnesses in Infants [J].
Lee, Wai-Ming ;
Kiesner, Christin ;
Pappas, Tressa ;
Lee, Iris ;
Grindle, Kris ;
Jartti, Tuomas ;
Jakiela, Bogdan ;
Lemanske, Robert F., Jr. ;
Shult, Peter A. ;
Gern, James E. .
PLOS ONE, 2007, 2 (10)
[10]   Real-time reverse transcription-PCR assay for comprehensive detection of human rhinoviruses [J].
Lu, Xiaoyan ;
Holloway, Brian ;
Dare, Ryan K. ;
Kuypers, Jane ;
Yagi, Shigeo ;
Williams, John V. ;
Hall, Caroline B. ;
Erdman, Dean D. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (02) :533-539