In vivo application of biodegradable controlled antibiotic release systems for the treatment of implant-related osteomyelitis

被引:120
作者
Gürsel, I
Korkusuz, F
Türesin, F
Alaeddinoglu, NG
Hasirci, V [1 ]
机构
[1] Middle E Tech Univ, Dept Sci Biol, Biotechnol Res Unit, TR-06531 Ankara, Turkey
[2] Middle E Tech Univ, Med Ctr, TR-06531 Ankara, Turkey
关键词
osteomyelitis; biodegradable controlled release systems; local antibiotic delivery; poly(hydroxybutyrate-co-hydroxyvalerate);
D O I
10.1016/S0142-9612(00)00170-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study the construction and in vivo testing of antibiotic-loaded polyhydroxyalkanoate rods were planned for use in the treatment of implant-related osteomyelitis. The rods were constructed of poly(3-hydroxybutyrare-co-3-hydroxyvalerate) and poly(3hydroxybutyrate-co-4-hydroxybutyrate), carrying 50% (w/w) Sulperazone(R) or Duocid(R). They were implanted in rabbit tibia in which implant-related osteomyelitis (IRO) had been induced with Staphylococcus aureus. The effectiveness of the antibiotics in the treatment of IRO was determined. The establishment of IRO with bacterial inoculation was complete after 3 weeks with 100% infection rate in all groups. There was no contamination or super-infection. Both antibiotics were found to be highly effective against the bacteria. Following the application of Sulperazone-P(3-HB-co-4-HB) rods, no infective agents could be isolated from the infection site within the 6-week test period, indicating complete treatment of the infection. Macroscopical evaluation at follow-up revealed no drainage, minimal swelling and increase in local warmth, most probably due to the surgery rather than to a reaction towards the implant. The overall scores for radiological findings by the end of 6 weeks were 0.8/5 for the antibiotic-loaded rod implanted in the right limb, and 1.1/5 For the antibiotic-free rod implanted in the left limb. There was no statistical difference between the antibiotic-loaded and antibiotic-free polymeric rods. In vivo drug release was almost complete within the first week. One interesting observation, however, was that the therapy was still very effective even when the release rate was very high. In the SEM of in vitro tested rods, the polymeric component was unchanged in 2 weeks while the drug leached out, leaving voids behind. In vivo, however, the morphology of the implant was significantly modified within 6 weeks post-implantation. Since a substantial degree of the in vivo drug release was complete within 1 week, we believe that dissolution of the drug must be the predominant mechanism through which the drug release is controlled. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 38 条
[1]   THE SUSTAINED-RELEASE OF ANTIMICROBIAL DRUGS FROM BONE-CEMENT - AN APPRAISAL OF LABORATORY INVESTIGATIONS AND THEIR SIGNIFICANCE [J].
BAYSTON, R ;
MILNER, RDG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (04) :460-464
[2]  
BUCHANAN JB, 1985, J FIELD ORNITHOL, V56, P265
[3]   FAILURE OF BIPOLAR HIP-ARTHROPLASTY SECONDARY TO RETAINED ANTIBIOTIC-IMPREGNATED POLYMETHYLMETHACRYLATE BEADS - A CASE-REPORT [J].
CALHOUN, J ;
DAUM, W ;
MADER, JT ;
KOULISIS, C ;
EVANS, EB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08) :1246-1248
[4]  
DAHNERS LE, 1987, CLIN ORTHOP RELAT R, P278
[5]   RUPTURED FEMORAL VEIN - A COMPLICATION OF THE USE OF GENTAMICIN BEADS IN AN INFECTED EXCISION ARTHROPLASTY OF THE HIP [J].
FIDDIAN, NJ ;
SUDLOW, RA ;
BROWETT, JP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (04) :493-494
[6]   POLYLACTIDE/POLYGLYCOLIDE ANTIBIOTIC IMPLANTS IN THE TREATMENT OF OSTEOMYELITIS - A CANINE MODEL [J].
GARVIN, KL ;
MIYANO, JA ;
ROBINSON, D ;
GIGER, D ;
NOVAK, J ;
RADIO, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (10) :1500-1506
[7]  
GUMUSYAZICI FZ, POLYHYDROXYBUTYRIC A
[8]   PROPERTIES AND DRUG-RELEASE BEHAVIOR OF POLY(3-HYDROXYBUTYRIC ACID) AND VARIOUS POLY(3-HYDROXYBUTYRATE-HYDROXYVALERATE) COPOLYMER MICROCAPSULES [J].
GURSEL, I ;
HASIRCI, V .
JOURNAL OF MICROENCAPSULATION, 1995, 12 (02) :185-193
[9]  
HOLLINGER JO, 1986, CLIN ORTHOP RELAT R, P290
[10]  
IKADA Y, 1985, Journal of Controlled Release, V2, P179, DOI 10.1016/0168-3659(85)90043-4