A radiopaque polymeric matrix for acrylic bone cements

被引:21
作者
Artola, A
Goñi, I
Gil, J
Ginebra, P
Manero, JM
Gurruchaga, M
机构
[1] Univ Basque Country, Fac Quim, POLYMAT, Inst Polymer Mat,Dpto Ciencia & Tecnol Polimeros, E-20080 San Sebastian, Spain
[2] Univ Barcelona, Escuela Ingn Ind, Dpto Ciencia Mat & Ing Met, E-08028 Barcelona, Spain
关键词
acrylic cement; radiopacity; iodophenol methacrylate; biocompatibility; mechanical properties;
D O I
10.1002/jbm.b.10511
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As part of the search for an alternative to inorganic radiopaque agents, this work studies the possibility of modifying bone cement formulations by incorporating a radiopaque monomer, that is, 4-iodophenol methacrylate (IPMA), in the liquid phase. The monomer was synthesized in the laboratory, and cements were prepared by the standard method. The influence on the different cement characteristics of various monomer concentrations was studied. It was seen that the setting time decreased as the percentage of monomer increased. The radiopacity attained in the 15 vol.% IPMA formulations was about the same as that for a cement containing 10 wt.% barium sulphate. Dynamic and static mechanical properties were measured. The materials did not show significant differences in the glass transition temperature. However, static mechanical properties showed enhanced compressive strength, tensile strength, and elastic modulus with respect to conventional cements formulated with barium sulphate. Histological studies showed a good response of muscular tissue to implanted specimens. (C) 2002 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 64B: 44-55, 2003.
引用
收藏
页码:44 / 55
页数:12
相关论文
共 23 条
[1]  
ABBOUD M, 1999, P 15 EUR C BIOM
[2]   WATER IN METHACRYLATES .1. SORPTION AND DESORPTION PROPERTIES OF POLY(2-HYDROXYETHYL METHACRYLATE-CO-GLYCOL DIMETHACRYLATE) NETWORKS [J].
ALLEN, PEM ;
BENNETT, DJ ;
WILLIAMS, DRG .
EUROPEAN POLYMER JOURNAL, 1992, 28 (04) :347-352
[3]  
BARRIE JA, 1968, DIFFUSION POLYM, P259
[4]   STRENGTH OF ACRYLIC BONE CEMENTS AND ACRYLIC CEMENT STAINLESS STEEL INTERFACES .1. STRENGTH OF ACRYLIC BONE CEMENT CONTAINING 2ND PHASE DISPERSIONS [J].
BEAUMONT, PWR .
JOURNAL OF MATERIALS SCIENCE, 1977, 12 (09) :1845-1852
[5]   MICROMECHANISMS OF FATIGUE-CRACK INITIATION AND PROPAGATION IN BONE CEMENTS [J].
BHAMBRI, SK ;
GILBERTSON, LN .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (02) :233-237
[6]  
BIKERMAN JJ, 1970, PHYSICAL SURFACES
[7]   WATER-ABSORPTION CHARACTERISTICS OF DENTAL MICROFINE COMPOSITE FILLING MATERIALS .1. PROPRIETARY MATERIALS [J].
BRADEN, M ;
CLARKE, RL .
BIOMATERIALS, 1984, 5 (06) :369-372
[8]  
Crank J., 1956, The Mathematics of Diffusion
[9]   COMPARISON OF THE FATIGUE CHARACTERISTICS OF CENTRIFUGED AND UNCENTRIFUGED SIMPLEX P-BONE CEMENT [J].
DAVIES, JP ;
BURKE, DW ;
OCONNOR, DO ;
HARRIS, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (03) :366-371
[10]  
FUJITA D, 1968, DIFFUSION POLYM, V3