Exogenous contrast agent improves sensitivity of gradient-echo functional magnetic resonance imaging at 9.4 T

被引:69
作者
Mandeville, JB
Jenkins, BG
Chen, YCI
Choi, JK
Kim, YR
Belen, D
Liu, C
Kosofsky, BE
Marota, JJA
机构
[1] MIT, Massachusetts Gen Hosp, HMS Athinoula A Martinos Ctr Biomed Imaging, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Dept Neurol, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Dept Anesthesia & Crit Care, Boston, MA 02114 USA
关键词
MRI; CBV; BOLD; brain;
D O I
10.1002/mrm.20278
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Relative to common clinical magnetic field strengths, higher fields benefit functional brain imaging both by providing additional signal for high-resolution applications and by improving the sensitivity of endogenous contrast due to the blood oxygen level dependent (BOLD) mechanism, which has limited detection power at low magnetic fields relative to the use of exogenous contrast agent. This study evaluates the utility of iron oxide contrast agent for gradient echo functional MRI at 9.4 T in rodents using cocaine and methylphenidate as stimuli. Relative to the BOLD method, the use of high iron doses and short echo times provided a roughly twofold global increase in functional sensitivity, while also suppressing large vessel signal and reducing susceptibility artifacts. Furthermore, MRI measurements of the functional percentage change in cerebral blood volume (CBV) showed excellent agreement with results obtained at much lower magnetic field strengths, demonstrating that MRI estimates of this quantity are roughly independent of magnetic field when appropriate techniques are employed. The derived field dependencies for relative sensitivity and MRI estimates of the percentage change in CBV suggest that the benefits provided by exogenous agents will persist even at much higher magnetic fields than 9.4 T. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:1272 / 1281
页数:10
相关论文
共 34 条
[1]   Functional recovery after brain lesion - contralateral neuromodulation: an fMRI study [J].
Abo, M ;
Chen, ZG ;
Lai, LJ ;
Reese, T ;
Bjelke, B .
NEUROREPORT, 2001, 12 (07) :1543-1547
[2]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[3]   Improved mapping of (pharmacologically induced neuronal activation using the IRON technique with superparamagnetic blood pool agents [J].
Chen, YCI ;
Mandeville, JB ;
Nguyen, TV ;
Talele, A ;
Cavagna, F ;
Jenkins, BG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (05) :517-524
[4]   Calibrated functional MRI: Mapping the dynamics of oxidative metabolism [J].
Davis, TL ;
Kwong, KK ;
Weisskoff, RM ;
Rosen, BR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (04) :1834-1839
[5]   Functional magnetic resonance imaging of reorganization in rat brain after stroke [J].
Dijkhuizen, RM ;
Ren, JM ;
Mandeville, JB ;
Wu, ON ;
Ozdag, FM ;
Moskowitz, MA ;
Rosen, BR ;
Finklestein, SP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (22) :12766-12771
[6]   Correlation between brain reorganization, ischemic damage, and neurologic status after transient focal cerebral ischemia in rats: A functional magnetic resonance imaging study [J].
Dijkhuizen, RM ;
Singhal, AB ;
Mandeville, JB ;
Wu, O ;
Halpern, EF ;
Finklestein, SP ;
Rosen, BR ;
Lo, EH .
JOURNAL OF NEUROSCIENCE, 2003, 23 (02) :510-517
[7]   Experimental determination of the BOLD field strength dependence in vessels and tissue [J].
Gati, JS ;
Menon, RS ;
Ugurbil, K ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :296-302
[8]   Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex [J].
Hoge, RD ;
Atkinson, J ;
Gill, B ;
Crelier, GR ;
Marrett, S ;
Pike, GB .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (16) :9403-9408
[9]  
Hoge RD, 1999, MAGNET RESON MED, V42, P849, DOI 10.1002/(SICI)1522-2594(199911)42:5<849::AID-MRM4>3.0.CO
[10]  
2-Z