Sensitive peroxyoxalate chemiluminescence determination of psychotropic indole derivatives

被引:8
作者
Cepas, J
Silva, M
PerezBendito, D
机构
[1] Department of Analytical Chemistry, Faculty of Sciences, University of Córdoba
关键词
chemiluminescence; peroxyoxalate; continuous addition; indole derivatives;
D O I
10.1039/an9962100049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The continuous-addition-of-reagent (CAR) technique was used for the determination of hallucinogenic alkaloids such as N-methyltryptamine, 5-methyltryptamine, alpha-methyltryptamine, bufotenine and psilocin by measuring the peroxyoxalate chemiluminescence produced on reaction with the bis(2,4,6-trichlorophenyl)oxalate-hydrogen peroxide system following derivatization with dansyl chloride. This is the first reported use of chemiluminescence for the determination of these compounds. The special ability of the CAR technique to suppress background emission in peroxyoxalate chemiluminescence reactions provides a highly sensitive means of determination (the response to indole alkaloids is linear over two orders of magnitude and detection limits are in the picomole range). The proposed method compares favourably with existing alternatives in terms of sensitivity and was validated in the determination of psilocin in mushroom samples.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 26 条
[1]  
BARRETT DA, 1991, J CHROMATOGR-BIOMED, V104, P135
[2]   IDENTIFICATION OF N,N-DIMETHYLTRYPTAMINE, 5-METHOXY-N,N-DIMETHYL-TRYPTAMINE AND BUFOTENIN BY CELLULOSE TLC [J].
BAUMANN, P ;
NARASIMHACHARI, N .
JOURNAL OF CHROMATOGRAPHY, 1973, 86 (01) :269-273
[3]   DETERMINATION OF TRYPTAMINE DERIVATIVES IN HALLUCINOGENIC MUSHROOMS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION [J].
BORNER, S ;
BRENNEISEN, R .
JOURNAL OF CHROMATOGRAPHY, 1987, 408 :402-408
[4]  
BOWMAN WC, 1980, TXB PHARM
[5]  
CANNMOISAN C, 1992, J CHROMATOGR-BIOMED, V112, P134
[6]  
CASALE JF, 1985, J FORENSIC SCI, V30, P247
[7]   IMPROVED PEROXYOXALATE CHEMILUMINESCENCE-BASED DETERMINATIONS BY USE OF CONTINUOUS REAGENT ADDITION TO REMOVE BACKGROUND EMISSION [J].
CEPAS, J ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :4079-4084
[8]   SCREENING OF HALLUCINOGENIC MUSHROOMS WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND MULTIPLE DETECTION [J].
CHRISTIANSEN, AL ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV) :293-299
[9]  
DELCASTILLO B, 1991, LUMINISCENCE TECHNIQ, P99
[10]  
DESIDERIO MA, 1987, J CHROMATOGR-BIOMED, V63, P285