The measurement of Henry's constant for hydrogen in high subcritical and supercritical aqueous systems

被引:21
作者
Eklund, K [1 ]
Lvov, SN [1 ]
Macdonald, DD [1 ]
机构
[1] Penn State Univ, Ctr Adv Mat, University Pk, PA 16802 USA
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1997年 / 437卷 / 1-2期
关键词
hydrogen fugacity; supercritical water; high temperatures; Henry's law constant;
D O I
10.1016/S0022-0728(97)00335-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Studies are reported on the Hg\HgO\ZrO2(Y2O3)/NaOH(aq)\H-2(Pt) cell at temperatures ranging from 298.15 K (25 degrees C) to 723.15 K (450 degrees C) and at a pressure of 275 bar, to assess the viability of ceramic sensors for measuring Henry's constant for hydrogen in high subcritical (473.15 K < T < 647.30 K) and supercritical (T > 647.30 K) aqueous systems. Previous work has shown that this cell is thermodynamically well-behaved, in that the measured potential is in good agreement with that calculated from thermodynamic data for the cell components. Thus, the Hg\HgO\ZrO2(Y2O3)\H+,H2O ceramic membrane electrode, when combined with a platinum electrode, provides a convenient means of evaluating hydrogen activity and Henry's constant for hydrogen in high subcritical and supercritical aqueous systems. The apparent standard Gibbs energies of formation of H,(aq) at temperatures within the range 473 and 723 K and at a pressure of 275 bar have been obtained. The calculated Henry's constants for dissolved molecular hydrogen in pure water were compared with the available literature data, and good agreement was found over the entire temperature range explored in this work. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:99 / 110
页数:12
相关论文
共 58 条
[1]  
[Anonymous], PHYSICAL CHEM AQUEOU
[2]   ACIDITY MEASUREMENTS AT ELEVATED TEMPERATURES .1. URANIUM(VI) HYDROLYSIS AT 25 AND 94 DEGREES1B [J].
BAES, CF ;
MEYER, NJ .
INORGANIC CHEMISTRY, 1962, 1 (04) :780-&
[3]  
BARNES HL, 1987, HYDROTHERMAL EXPT TE, P507
[4]  
BOURCIER WL, 1987, HYDROTHERMAL EXPT TE, P157
[5]   Direct pH measurement of NaCl-bearing fluid with an in situ sensor at 400 degrees C and 40 megapascals [J].
Ding, K ;
Seyfried, WE .
SCIENCE, 1996, 272 (5268) :1634-1636
[6]   IN-SITU MEASUREMENT OF DISSOLVED H-2 IN AQUEOUS FLUID AT ELEVATED-TEMPERATURES AND PRESSURES [J].
DING, K ;
SEYFRIED, WE .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1995, 59 (22) :4769-4773
[7]   Gold as a hydrogen sensing electrode for in situ measurement of dissolved H-2 in supercritical aqueous fluid [J].
Ding, K ;
Seyfried, WE .
JOURNAL OF SOLUTION CHEMISTRY, 1996, 25 (05) :421-433
[8]   POTENTIALS OF PALLADIUM HYDRIDE REFERENCE ELECTRODE BETWEEN 25 DEGREES AND 195 DEGREES C [J].
DOBSON, JV .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1972, 35 (NMAR) :129-&
[9]   EMF-MEASUREMENTS OF CELLS EMPLOYING METAL-METAL OXIDE ELECTRODES IN AQUEOUS CHLORIDE AND SULFATE ELECTROLYTES AT TEMPERATURES BETWEEN 25-250DEGREESC [J].
DOBSON, JV ;
SNODIN, PR ;
THIRSK, HR .
ELECTROCHIMICA ACTA, 1976, 21 (07) :527-533
[10]  
DOLIDZE VA, 1987, ION SELECTIVE ELECTR, P57