Evaluation of Anatomic Valve Opening and Leaflet Morphology in Aortic Valve Bioprosthesis by Using Multidetector CT: Comparison with Transthoracic Echocardiography

被引:52
作者
Chenot, Fabien [1 ]
Montant, Patrick [1 ]
Goffinet, Celine [1 ]
Pasquet, Agnes [1 ]
Vancraeynest, David [1 ]
Coche, Emmanuel [2 ]
Vanoverschelde, Jean-Louis [1 ]
Gerber, Bernhard L. [1 ]
机构
[1] Catholic Univ Louvain, Clin Univ St Luc, Div Cardiol, B-1200 Brussels, Belgium
[2] Catholic Univ Louvain, Clin Univ St Luc, Div Radiol, B-1200 Brussels, Belgium
关键词
CORONARY-ARTERY-DISEASE; ROW COMPUTED-TOMOGRAPHY; PROSTHESIS-PATIENT MISMATCH; DIAGNOSTIC PERFORMANCE; CONTINUITY EQUATION; HEART-VALVE; MYOCARDIAL-INFARCTION; MAGNETIC-RESONANCE; ANGIOGRAPHY; AREA;
D O I
10.1148/radiol.0000082294
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To prospectively determine whether cardiac-gated multidetector computed tomography (CT) allows visualization of aortic valve leaflets after bioprosthetic aortic valve replacement (AVR), to provide an accurate method for measuring the aortic valve opening, and to provide morphologic and functional information regarding the mechanism underlying poor function of the bioprosthetic valve. Materials and Methods: The institutional review board approved the study protocol; informed consent was given. Fifty-four patients (27 men; mean age, 75 years 6 8 [standard deviation]) with bioprosthetic AVR implanted 2 years 6 3 earlier underwent 64-section CT and transthoracic echocardiography (TTE). Two blinded observers manually planimetered the aortic valve area (AVA) by using a computer workstation on end-systolic short-axis CT images and measured opening angles (OAs) between the bioprosthesis annulus base and the free margin on long-axis images. These measurements were compared with those of the effective orifice area (EOA) of the valve at Doppler continuity-equation TTE by using regression and Bland-Altman methods. Morphology and mobility of leaflets in normally functioning (EOA indexed to body surface area [EOA(i)] > 0.65 cm(2)/m(2)) and dysfunctional (EOA(i) < 0.65 cm(2)/m(2)) AVRs were compared. Results: AVA at CT correlated highly to EOA at TTE (r = 0.93, P < .001) but was significantly larger (1.2 cm(2) +/- 0.4 vs 1.1 cm(2) +/- 0.3, P < .001) than EOA at TTE. In dysfunctional bioprostheses (n = 34), CT results showed a variety of morphologic abnormalities, such as leaflet thickening (n = 9), presumed thrombotic material (n = 6), and leaflet calcification (n = 1). Multidetector CT results demonstrated restriction of leaflet motion indicated by lower OA (64 degrees +/- 5 vs 79 degrees +/- 3, P < .0001) in dysfunctional AVRs than in normally functioning AVRs (n = 11). Conclusion: Sixty-four-section CT can help accurately measure AVA in bioprosthetic AVR compared with EOA at TTE. It can also show morphologic abnormalities and reduced leaflet motion in a dysfunctional bioprosthesis, thereby potentially unraveling the mechanism of dysfunction. (C) RSNA, 2009
引用
收藏
页码:377 / 385
页数:9
相关论文
共 31 条
[1]
American College of Cardiology, 2006, J Am Coll Cardiol, V48, pe1, DOI 10.1016/j.jacc.2006.05.021
[2]
[Anonymous], EUR RADIOL
[3]
Prosthetic valve obstruction: Diagnostic usefulness of cineradiography and multidetector-row computed tomography [J].
Aoyagi, S. ;
Fukunaga, S. ;
Arinaga, K. ;
Shojima, T. ;
Ueda, T. .
THORACIC AND CARDIOVASCULAR SURGEON, 2007, 55 (08) :517-519
[4]
Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[5]
12-YEAR COMPARISON OF A BJORK-SHILEY MECHANICAL HEART-VALVE WITH PORCINE BIOPROSTHESES [J].
BLOOMFIELD, P ;
WHEATLEY, DJ ;
PRESCOTT, RJ ;
MILLER, HC .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (09) :573-579
[6]
Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[7]
Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations - A numerical study [J].
DeGroff, CG ;
Shandas, R ;
Valdes-Cruz, L .
CIRCULATION, 1998, 97 (16) :1597-1605
[8]
Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[9]
Characterization of acute and chronic myocardial infarcts by multidetector computed tomography - Comparison with contrast-enhanced magnetic resonance [J].
Gerber, BL ;
Belge, B ;
Legros, GJ ;
Lim, P ;
Poncelet, A ;
Pasquet, AS ;
Gisellu, G ;
Coche, E ;
Vanoverschelde, JLJ .
CIRCULATION, 2006, 113 (06) :823-833
[10]
Differences in Aortic Valve Area Measured with CT Planimetry and Echocardiography (Continuity Equation) Are Related to Divergent Estimates of Left Ventricular Outflow Tract Area [J].
Halpern, Ethan J. ;
Mallya, Raghuram ;
Sewell, Matthew ;
Shulman, Matisyahu ;
Zwas, Donna R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (06) :1668-1673