Measuring anterior chamber depth with the Orbscan Topography System

被引:81
作者
Auffarth, GU
Tetz, MR
Biazid, Y
Volcker, HE
机构
[1] Department of Ophthalmology, Ruprecht-Karls-Univ. of Heidelberg, D-69120 Heidelberg
关键词
D O I
10.1016/S0886-3350(97)80114-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reliability of the Orbscan Topography System in measuring anterior chamber depth (ACD). Setting: Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany. Methods: The Orbscan Topography System is a 3-D, scanning slit beam system for analyzing corneal surfaces as well as structures of the anterior segment, e.g., iris, lens. Reflected surface data points are measured in the x, y, and z axes, creating color-coded true surface topography maps. We measured ACD prior to cataract surgery in 56 eyes of 37 patients (mean age 70.4 years + 13.2 [SD]) using the Orbscan system and, as a control, the Grieshaber Biometric System (ultrasound) and the Jager ACD slitlamp measurement system. Results: Mean ACD values measured with the Orbscan system were 3.23 +/- 0.55 mm; ultrasound measurements were 3.27 +/- 0.54 mm and Jager measurements, 3.10 +/- 0.55 mm. The average difference between Orbscan and ultrasound values was 0.04 +/- 0.15 mm. The correlation coefficient between Orbscan and ultrasound was 0.96 (P < .00001) and between Orbscan and Jager, 0.899 (P < .0001). Conclusion: The ACD measurements by the Orbscan system were equivalent to common reference measurements.
引用
收藏
页码:1351 / 1355
页数:5
相关论文
共 22 条
[1]  
ARAI M, 1994, ACTA OPHTHALMOL, V72, P694
[2]  
BAEZ KA, 1992, OPHTHALMIC SURG LAS, V23, P426
[3]  
CARONIA RM, 1996, AM J OPHTHALMOL, V112, P53
[4]  
Congdon NG, 1996, ACTA OPHTHALMOL SCAN, V74, P113
[5]   OCULAR DIMENSIONS AND REFRACTION IN TIBETAN CHILDREN [J].
GARNER, LF ;
YAP, MKH ;
KINNEAR, RF ;
FRITH, MJ .
OPTOMETRY AND VISION SCIENCE, 1995, 72 (04) :266-271
[6]  
GARNER LF, 1995, OPTOM VIS SCI, V72, P425
[7]   Achieving emmetropia in extremely short eyes with two piggyback posterior chamber intraocular lenses [J].
Holladay, JT ;
Gills, JP ;
Leidlein, J ;
Cherchio, M .
OPHTHALMOLOGY, 1996, 103 (07) :1118-1123
[8]   EFFECT OF PILOCARPINE ON ANTERIOR-CHAMBER ANGLES [J].
HUNG, L ;
YANG, CH ;
CHEN, MS .
JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 1995, 11 (03) :221-226
[9]   GROWTH OF THE INTERNAL AND EXTERNAL EYE IN TERM AND PRETERM INFANTS [J].
ISENBERG, SJ ;
NEUMANN, D ;
CHEONG, PYY ;
LING, YLF ;
MCCALL, LC ;
ZIFFER, AJ .
OPHTHALMOLOGY, 1995, 102 (05) :827-830
[10]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589