Determination of Pb and Cu by anodic stripping voltammetry using glassy carbon electrodes modified with mercury or mercury-nafion films

被引:17
作者
Merkoçi, A [1 ]
Vasjari, M
Fàbregas, E
Alegret, S
机构
[1] Univ Autonoma Barcelona, Dept Quim, Grp Sensors & Biosensors, Bellaterra 08193, Catalonia, Spain
[2] Univ Tirana, Fac Nat Sci, Dept Chem, Tirana, Albania
关键词
lead; cooper; anodic stripping voltammetry; mercury film; nafion;
D O I
10.1007/s006040070015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different approaches for the modification of glassy carbon electrodes using a mercury film and mercury-nafion are compared. The mixture of mercury(II) chloride solution with a nafion solution diluted in ethanol is used to coat the polished glassy carbon surface. The modified working electrodes are compared when measuring Pb and Cu in real seawater samples. An optimisation of the parameters during the formation of the films was done to obtain well-defined stripping peaks. The type of inert supporting electrolyte and the pH play an important role on the sensitivity of the measurement. Results for Pb and Cu determinations show the advantages of Hg-nafion modification as an alternative method. These advantages include a shorter modification time, the avoidance of Hg solutions during the formation of the Hg film and an improved sensitivity for Pb determination.
引用
收藏
页码:29 / 33
页数:5
相关论文
共 14 条
[1]   DEVELOPMENT OF A POLYMER-DISPERSED MERCURY MODIFIED ELECTRODE [J].
GE, HL ;
ZHAO, HJ ;
WALLACE, GG .
ANALYTICA CHIMICA ACTA, 1990, 238 (02) :345-350
[2]   SIGNAL STABILITY OF NAFION-COATED THIN MERCURY FILM ELECTRODES FOR STRIPPING VOLTAMMETRY [J].
HOYER, B ;
JENSEN, N .
TALANTA, 1994, 41 (03) :449-453
[3]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES IN ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM ;
BATLEY, GE .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1608-1614
[4]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES TO THE DIRECT DETERMINATION OF TRACE-METALS IN BODY-FLUIDS BY ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM .
ANALYTICAL CHEMISTRY, 1987, 59 (24) :2839-2842
[5]   APPLICABILITY OF CHEMICALLY-MODIFIED ELECTRODES FOR DETERMINATION OF COPPER SPECIES IN NATURAL-WATERS [J].
LABUDA, J ;
VANICKOVA, M ;
UHLEMANN, E ;
MICKLER, W .
ANALYTICA CHIMICA ACTA, 1994, 284 (03) :517-523
[6]   APPLICATION OF A NAFION-SCHIFF BASE MODIFIED ELECTRODE IN ANODIC-STRIPPING VOLTAMMETRY FOR THE DETERMINATION OF TRACE AMOUNTS OF MERCURY [J].
LIU, KZ ;
WU, QG ;
LIU, HI .
ANALYST, 1990, 115 (06) :835-837
[7]   DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE BISMUTH IN MINERALS WITH NAFION MERCURY FILM MODIFIED ELECTRODE [J].
LIU, KZ ;
WU, QG .
ELECTROANALYSIS, 1992, 4 (05) :569-573
[8]  
MACCA C, 1997, ANAL LET, V33, P1223
[9]   ELECTROCHEMICAL SPECIATION ANALYSIS OF METALS AT MEMBRANE-COATED ELECTRODES [J].
MORRISON, GMP ;
FLORENCE, TM .
ELECTROANALYSIS, 1989, 1 (06) :485-491
[10]   COMPARISON OF PHYSICOCHEMICAL SPECIATION PROCEDURES WITH METAL TOXICITY TO CHLORELLA-PYRENOIDOSA - COPPER COMPLEXATION CAPACITY [J].
MORRISON, GMP ;
FLORENCE, TM .
ELECTROANALYSIS, 1989, 1 (02) :107-112