Integrated electrochemical gluconic acid biosensor based on self-assembled monolayer-modified gold electrodes.: Application to the analysis of gluconic acid in musts and wines

被引:17
作者
Campuzano, S. [1 ]
Gamella, M. [1 ]
Serra, B. [1 ]
Reviejo, A. J. [1 ]
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
self-assembled monolayers; enzyme biosensors; gluconic acid; wines;
D O I
10.1021/jf063073w
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
An integrated amperometric gluconic acid biosensor constructed using a gold electrode (AuE) modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA) on which gluconate dehydrogenase (GADH, 0.84 U) and the mediator tetrathiafulvalene (TTF, 1.5 mu mol) were coimmobilized by covering the electrode surface with a dialysis membrane is reported. The working conditions selected were E-app = +0.15 V and 25 +/- 1 degrees C. The useful lifetime of one single TTF-GADH-MPA-AuE was surprisingly long. After 53 days of continuous use, the biosensor exhibited 86% of the original sensitivity. A linear calibration plot was obtained for gluconic acid over the 6.0 x 10(-7) to 2.0 x 10(-5) M concentration range, with a limit of detection of 1.9 x 10(-7) M. The effect of potential interferents (glucose, fructose, galactose, arabinose, and tartaric, citric, malic, ascorbic, gallic, and caffeic acids) on the biosensor response was evaluated. The behavior of the biosensor in a flow-injection system in connection with amperometric detection was tested. The analytical usefulness of the biosensor was evaluated by determining gluconic acid in wine and must samples, and the results obtained were validated by comparison with those provided by using a commercial enzyme test kit.
引用
收藏
页码:2109 / 2114
页数:6
相关论文
共 22 条
[1]   Gluconic acid, its lactones, and SO2 binding phenomena in musts from botrytized grapes [J].
Barbe, JC ;
de Revel, G ;
Bertrand, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (22) :6408-6412
[2]   NEW ELECTROCATALYTIC BIOMOLECULAR INTERFACE FOR FABRICATING A FRUCTOSE DEHYDROGENASE-BASED SENSING SYSTEM [J].
BEGUM, A ;
KOBATAKE, E ;
SUZAWA, T ;
IKARIYAMA, Y ;
AIZAWA, M .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :31-36
[3]   An integrated electrochemical fructose biosensor based on tetrathiafulvalene-modified self-assembled monolayers on gold electrodes [J].
Campuzano, S ;
Gaálvez, R ;
Pedrero, M ;
Manuel de Villena, FJ ;
Pingarrón, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) :600-607
[4]   Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode [J].
Campuzano, S ;
Gálvez, R ;
Pedero, M ;
de Villena, FJM ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2) :92-100
[5]   Determination of electroactive organic acids by anion-exchange chromatography using a copper modified electrode [J].
Casella, IG ;
Gatta, M .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (02) :223-233
[6]   SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ORGANIC-ACIDS IN HONEY [J].
CHERCHI, A ;
SPANEDDA, L ;
TUBEROSO, C ;
CABRAS, P .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :59-64
[7]   Determination of carboxylic acids in vinegars and in Aceto Balsamico Tradizionale di Modena by HPLC and GC methods [J].
Cocchi, M ;
Lambertini, P ;
Manzini, D ;
Marchetti, A ;
Ulrici, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (19) :5255-5261
[8]  
Couto J, 2003, 7 S INT OEN BORD
[9]   Biosensors based on membrane-bound enzymes immobilized in a 5-(octyldithio)-2-nitrobenzoic acid layer on gold electrodes [J].
Darder, M ;
Casero, E ;
Pariente, F ;
Lorenzo, E .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3784-3792
[10]   Applications of laccases and tyrosinases (phenoloxidases) immobilized on different supports:: a review [J].
Durán, N ;
Rosa, MA ;
D'Annibale, A ;
Gianfreda, L .
ENZYME AND MICROBIAL TECHNOLOGY, 2002, 31 (07) :907-931