Is there a relationship between light touch-pressure sensation and functional hand ability?

被引:31
作者
Melchior, Hanna
Vatine, Jean-Jacques
Weiss, Patrice L. [1 ]
机构
[1] Univ Haifa, Fac Social Welf & Hlth Studies, Dept Occupat Therapy, IL-31999 Haifa, Israel
[2] Israel Hansens Dis Ctr, Jerusalem, Israel
[3] Shaare Zedek Med Ctr, Dept Occupat Therapy, Jerusalem, Israel
[4] Reuth Med Ctr, Outpatient & Res Div, Tel Aviv, Israel
[5] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
关键词
Semmes Weinstein monofilament test; light touch sensation; hand function;
D O I
10.1080/09638280600902547
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose. To investigate and compare the level of light touch-pressure sensation as tested via the Semmes Weinstein monofilament (SWM) test with the level of functional hand ability. Methods. Twenty-seven persons with isolated sensory deficit due to leprosy and 31 healthy controls were tested in the Occupational Therapy department of a hospital for patients with Hansen's disease. Palmar light touch thresholds were determined by SMW testing. Functional hand ability was tested via the Jebsen-Taylor Hand Function Test (JTHFT) and the Functional Dexterity Test (FDT). All participants were measured by manual muscle testing (MMT) to exclude any motor impairment. Data analysis compared sensory thresholds and level of functional hand ability between the two groups and examined the relationship between the variables. Results. In the group with sensory deficit, the sensory thresholds were significantly higher than in the control group. Significant correlations were found between the sensory thresholds measured by the SWM test and the FDT and JTHFT scores, with higher correlations found for tasks entailing manipulation of small objects. Conclusions. The findings support the existence of a relationship between sensory light touch thresholds tested by the Semmes Weinstein monofilaments (SWMs) and hand function. However, the SWM test alone is not sufficient as an indicator of hand function and must therefore be supplemented with other hand function tests.
引用
收藏
页码:567 / 575
页数:9
相关论文
共 51 条
[1]  
Aaron DH, 1983, J HAND SURG A, V8, P627
[2]  
Aaron Dorit H, 2003, J Hand Ther, V16, P12
[3]  
Anderson A, 1998, INT J LEPROSY, V66, p69A
[4]  
Anderson AM, 1999, LEPROSY REV, V70, P305
[5]  
[Anonymous], 1990, REHABILITATION HAND
[6]  
[Anonymous], PRINCIPLES NEURAL SC
[7]  
[Anonymous], 1991, Journal of Hand Therapy
[8]  
Bell-Krotoski J, 1995, REHABILITATION HAND, P109
[9]   THE REPEATABILITY OF TESTING WITH SEMMES-WEINSTEIN MONOFILAMENTS [J].
BELLKROTOSKI, J ;
TOMANCIK, E .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (01) :155-161
[10]  
BENSHAHAR R, 1998, WORK, V11, P315