Objective. The condylar region is one of the most frequent sites for mandibular fractures, with direct application of miniplates being the most commonly used open-fixation technique today. Yet, anatomic and biomechanical limitations continue to make this application technically challenging with a considerable complication rate. We sought to analyze such incongruencies with respect to the complex biomechanical behavior of the mandible. Study design. Individual human mandible geometry, the specific bone density distribution, and the position and orientation of the masticatory muscles were evaluated by performing computed tomography scans and a sequential dissection of the cadaver mandible. Three-dimensional finite-element analysis was performed for different fracture sites, osteosynthesis plates, and loading conditions. Results. Osteosynthesis of fractures of the condylar neck with I or 2 miniplates of a diameter of 2.35 X 1.00 mm was found to be an insufficient fixation method. This also applies for plates (3.60 X 1.54 mm), according to Pape et al,(8) when used in singular fashion (high condylar neck fractures excepted). In cases of singular occlusal contacts in the molar region (particularly at the contralateral side of the fracture), the highest stress values inside the mandible and osteosynthetic devices could be observed. With even the static yield limit of titanium being exceeded in such cases, consecutive rapid failure of the miniplates becomes most likely when loading of the condylar region caused by bite forces cannot be prevented. Conclusion. We strongly recommend the use, whenever possible, of 2 plates in the manner described by Pape et al(8) for osteosynthesis of fractures of the condylar neck in combination with bicortically placed screws. The stiffness of a singular osteosynthesis plate made of titanium in a diametrical dimension of approximately 5.0 X 1.75 mm was found to be equivalent to the physiological bone stiffness in the investigated fracture sites. The actual stiffness of such a fixation plate is approximately 3 times higher than the stiffness of devices commonly in use.
引用
收藏
页码:678 / 686
页数:9
相关论文
共 28 条
[1]  
ANDERSON D J, 1956, J Dent Res, V35, P664, DOI 10.1177/00220345560350050201
[2]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[3]  
Choi BH, 2001, J ORAL MAXIL SURG, V59, P734, DOI 10.1053/joms.2001.24283
[4]  
Eckelt U, 1981, Zahn Mund Kieferheilkd Zentralbl, V69, P485
[5]   RIGID FIXATION OF MANDIBULAR CONDYLE FRACTURES [J].
ELLIS, E ;
DEAN, J .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1993, 76 (01) :6-15
[6]   Osteosynthesis of condylar neck fractures: a review of 30 patients [J].
Hammer, B ;
Schier, P ;
Prein, J .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1997, 35 (04) :288-291
[7]   MODELING THE BIOMECHANICS OF THE MANDIBLE - A 3-DIMENSIONAL FINITE-ELEMENT STUDY [J].
HART, RT ;
HENNEBEL, VV ;
THONGPREDA, N ;
VANBUSKIRK, WC ;
ANDERSON, RC .
JOURNAL OF BIOMECHANICS, 1992, 25 (03) :261-286
[8]   TREATMENT OF FRACTURES OF ARTICULAR PROCESS BY FUNCTIONAL STABLE OSTEOSYNTHESIS USING MINIATURIZED DYNAMIC COMPRESSION PLATES [J].
KOBERG, WR ;
MOMMA, WG .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1978, 7 (04) :256-262
[9]   SURGICAL VERSUS CONSERVATIVE TREATMENT OF UNILATERAL CONDYLAR PROCESS FRACTURES - CLINICAL AND RADIOGRAPHIC EVALUATION OF 80 PATIENTS [J].
KONSTANTINOVIC, VS ;
DIMITRIJEVIC, B .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (04) :349-352
[10]   Modeling the mechanical behavior of the jaws and their related structures by finite element (FE) analysis [J].
Korioth, TWP ;
Versluis, A .
CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 1997, 8 (01) :90-104