Length-normalized pulse photoplethysmography: A noninvasive method to measure blood hemoglobin

被引:37
作者
Aldrich, TK
Moosikasuwan, M
Shah, SD
Deshpande, KS
机构
[1] Montefiore Med Ctr, Div Pulm Med, Bronx, NY 10467 USA
[2] Albert Einstein Coll Med, Bronx, NY 10467 USA
[3] Montefiore Med Ctr, Crit Care Med Div, Bronx, NY 10467 USA
关键词
anemia; clinical monitoring; pulse oximetry; sonomicrometry; optical properties; absorption;
D O I
10.1114/1.1527046
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To determine whether blood hemoglobin concentration ([Hb]) could be measured noninvasively as the ratio of pulsatile changes in attenuation (absorbance plus scatter) of light (D) across a body part to changes in light path length (l), we measured transmission of near-infrared light (905 +/- 10 nm) through a finger, using a modified pulse oximeter, and simultaneously monitored fingertip diameter, using a sonomicrometer. In 25 subjects with [Hb] ranging from 3.1 to 18.2 gm/dl, and with normal oxygenation, average D/l ratio over 30-60 s correlated strongly with [Hb] measured by Coulter counter (r = 0.84, p much less than 0.001), though with considerable scatter, with absolute value of differences averaging 17% of the mean. Using 12 gm/dl and 0.75 mm(-1) as the lower limits of normal for [Hb] and D/l, respectively, two of nine normals had low (D/l) (78% specificity), and only one of 16 anemic subjects had borderline normal (D/l) (94%-100% sensitivity). The positive predictive value of a low (D/l) was 88% and the negative predictive value was 87.5%. With further development, this technique may reduce the need for phlebotomy, thereby reducing risks and costs and improving the experience of being a patient. (C) 2002 Biomedical Engineering Society.
引用
收藏
页码:1291 / 1298
页数:8
相关论文
共 23 条
[1]   LIGHT-ABSORBING AND SCATTERING PROPERTIES OF NON-HAEMOLYSED BLOOD [J].
ANDERSON, NM ;
SEKELJ, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1967, 12 (02) :170-&
[2]   EFFECTS OF METHEMOGLOBINEMIA ON PULSE OXIMETRY AND MIXED VENOUS OXIMETRY [J].
BARKER, SJ ;
TREMPER, KK ;
HYATT, J .
ANESTHESIOLOGY, 1989, 70 (01) :112-117
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Simultaneous measurement of total hemoglobin and its derivatives in blood using CO-oximeters: Analytical principles; Their application in selecting analytical wavelengths and reference methods; A comparison of the results of the choices made [J].
Brunelle, JA ;
Degtiarov, AM ;
Moran, RF ;
Race, LA .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1996, 56 :47-69
[5]   Pulse oximetry:: An improved in vitro model that reduces blood flow-related artifacts [J].
Edrich, T ;
Flaig, M ;
Knitza, R ;
Rall, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (03) :338-343
[6]  
FROJMOVIC MM, 1975, J LAB CLIN MED, V86, P326
[7]  
GRAVENSTEIN D, 1994, ANESTHESIOLOGY, V81, pA576
[8]   Noninvasive total hemoglobin measurement [J].
Jeon, KJ ;
Kim, SJ ;
Park, KK ;
Kim, JW ;
Yoon, G .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) :45-50
[9]   Continuous monitoring of hematocrit values during apheresis for allogeneic peripheral blood stem cell collection [J].
Kajiume, T ;
Kawano, Y ;
Takaue, Y ;
Abe, T ;
Okamoto, Y ;
Makimoto, A ;
Watanabe, T ;
Sato, J ;
Yokobayashi, A ;
Kuroda, Y .
JOURNAL OF HEMATOTHERAPY, 1998, 7 (06) :493-497
[10]   Measurement of hemoglobin concentrations using the Astrim™ noninvasive blood vessel monitoring apparatus [J].
Kinoshita, Y ;
Yamane, T ;
Takubo, T ;
Kanashima, H ;
Kamitani, T ;
Tatsumi, N ;
Hino, M .
ACTA HAEMATOLOGICA, 2002, 108 (02) :109-110