Particle number size distributions in urban air before and after volatilisation

被引:50
作者
Birmili, W. [1 ]
Heinke, K. [1 ,2 ]
Pitz, M. [3 ,4 ]
Matschullat, J. [2 ]
Wiedensohler, A. [1 ]
Cyrys, J. [3 ,4 ]
Wichmann, H. -E. [3 ]
Peters, A. [3 ]
机构
[1] Leibniz Inst Tropospher Res IfT, D-04318 Leipzig, Germany
[2] TU Bergakad Freiberg, Interdisciplinary Environm Res Ctr IOZ, D-09599 Freiberg, Germany
[3] Helmholtz Zentrum Munchen HMGU, German Res Ctr Environm Hlth, Inst Epidemiol, D-85758 Neuherberg, Germany
[4] Univ Augsburg, Ctr Sci & Environm, D-86159 Augsburg, Germany
关键词
ULTRAFINE PARTICLES; PARTICULATE MATTER; ABSORPTION PHOTOMETRY; ATMOSPHERIC PARTICLES; ELEMENTAL COMPOSITION; AEROSOL VOLATILITY; VEHICLE EMISSIONS; EUROPEAN CITIES; STREET CANYON; POLLUTION;
D O I
10.5194/acp-10-4643-2010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Aerosol particle number size distributions (size range 0.003-10 mu m) in the urban atmosphere of Augsburg (Germany) were examined with respect to the governing anthropogenic sources and meteorological factors. The two-year average particle number concentration between November 2004 and November 2006 was 12 200 cm(-3), i.e. similar to previous observations in other European cities. A seasonal analysis yielded twice the total particle number concentrations in winter as compared to summer as consequence of more frequent inversion situations and enhanced particulate emissions. The diurnal variations of particle number were shaped by a remarkable maximum in the morning during the peak traffic hours. After a mid-day decrease along with the onset of vertical mixing, an evening concentration maximum could frequently be observed, suggesting a re-stratification of the urban atmosphere. Overall, the mixed layer height turned out to be the most influential meteorological parameter on the particle size distribution. Its influence was even greater than that of the geographical origin of the prevailing synoptic-scale air mass. Size distributions below 0.8 mu m were also measured downstream of a thermodenuder (temperature: 300 degrees C), allowing to retrieve the volume concentration of non-volatile compounds. The balance of particle number upstream and downstream of the thermodenuder suggests that practically all particles > 12 nm contain a non-volatile core while additional nucleation of particles smaller than 6 nm could be observed after the thermodenuder as an interfering artifact of the method. The good correlation between the non-volatile volume concentration and an independent measurement of the aerosol absorption coefficient (R-2=0.9) suggests a close correspondence of the refractory and light-absorbing particle fractions. Using the 'summation method', an average diameter ratio of particles before and after volatilisation could be determined as a function of particle size. The results indicated that particles > 60 nm contain a significantly higher fraction of non-volatile compounds, most likely black carbon, than particles < 60 nm. The results are relevant for future health-related studies in that they explore the size distribution and time-dependent behaviour of the refractory component of the urban aerosol over an extended time period.
引用
收藏
页码:4643 / 4660
页数:18
相关论文
共 83 条
  • [1] Aerosol particle number concentration measurements in five European cities using TSI-3022 condensation particle counter over a three-year period during health effects pollution on susceptible subpopulations
    Aalto, P
    Hämeri, K
    Paatero, P
    Kulmala, M
    Bellander, T
    Berglind, N
    Bouso, L
    Castano-Vinyals, G
    Sunyer, J
    Cattani, G
    Marconi, A
    Cyrys, J
    von Klot, S
    Peters, A
    Zetzsche, K
    Lanki, T
    Pekkanen, J
    Nyberg, F
    Sjövall, B
    Forastiere, F
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2005, 55 (08) : 1064 - 1076
  • [2] Aerosol volatility measurement using an improved thermodenuder: Application to secondary organic aerosol
    An, Woo Jin
    Pathak, Ravi K.
    Lee, Byong-Hyoek
    Pandis, Spyros N.
    [J]. JOURNAL OF AEROSOL SCIENCE, 2007, 38 (03) : 305 - 314
  • [3] [Anonymous], 2004, TECHNICAL REPORT
  • [4] Design of a DMA-based size spectrometer for a large particle size range and stable operation
    Birmili, W
    Stratmann, F
    Wiedensohler, A
    [J]. JOURNAL OF AEROSOL SCIENCE, 1999, 30 (04) : 549 - 553
  • [5] Atmospheric particle number size distribution in central Europe: Statistical relations to air masses and meteorology
    Birmili, W
    Wiedensohler, A
    Heintzenberg, J
    Lehmann, K
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2001, 106 (D23) : 32005 - 32018
  • [6] Birmili W, 2009, GEFAHRST REINHALT L, V69, P137
  • [7] Dispersion of traffic-related exhaust particles near the Berlin urban motorway - estimation of fleet emission factors
    Birmili, W.
    Alaviippola, B.
    Hinneburg, D.
    Knoth, O.
    Tuch, T.
    Borken-Kleefeld, J.
    Schacht, A.
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2009, 9 (07) : 2355 - 2374
  • [8] Birmili W, 2009, BOREAL ENVIRON RES, V14, P458
  • [9] Separation of volatile and non-volatile aerosol fractions by thermodesorption:: instrumental development and applications
    Burtscher, H
    Baltensperger, U
    Bukowiecki, N
    Cohn, P
    Hüglin, C
    Mohr, M
    Matter, U
    Nyeki, S
    Schmatloch, V
    Streit, N
    Weingartner, E
    [J]. JOURNAL OF AEROSOL SCIENCE, 2001, 32 (04) : 427 - 442
  • [10] Primary particle formation from vehicle emissions during exhaust dilution in the roadside atmosphere
    Charron, A
    Harrison, RM
    [J]. ATMOSPHERIC ENVIRONMENT, 2003, 37 (29) : 4109 - 4119