摘要
A cryogenic radiometer has been revised and examined in order to improve the absolute measurement of soft X-ray intensities. The uncertainty of the temperature rise in the cavity absorber has decreased to 0.2% through an increase in the thermal responsivity and through the suppression of the fluctuation in the back ground temperature.
引用
收藏
页码:1129 / +
页数:2
相关论文
共 12 条
[1]   REEVALUATION OF THE W-VALUE FOR ELECTRONS IN DRY AIR [J].
BOUTILLON, M ;
PERROCHEROUX, AM .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (02) :213-219
[2]   ATOMIC INNER-SHELL LEVEL ENERGIES DETERMINED BY ABSORPTION SPECTROMETRY WITH SYNCHROTRON RADIATION [J].
BREINIG, M ;
CHEN, MH ;
ICE, GE ;
PARENTE, F ;
CRASEMANN, B .
PHYSICAL REVIEW A, 1980, 22 (02) :520-528
[3]   NEW FAR UV DETECTOR CALIBRATION FACILITY AT THE NATIONAL BUREAU OF STANDARDS [J].
CANFIELD, LR .
APPLIED OPTICS, 1987, 26 (18) :3831-3837
[4]   PERFORMANCE OF THE COOLING SYSTEM FOR THE SOFT-X-RAY DOUBLE-CRYSTAL MONOCHROMATOR AT THE PHOTON FACTORY [J].
FUNABASHI, M ;
NOMURA, M ;
KITAJIMA, Y ;
YOKOYAMA, T ;
OHTA, T ;
KURODA, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1983-1986
[5]  
Gohshi Y, 1996, APPL SYNCHROTRON RAD
[6]   Recent performances of the soft x-ray crystal monochromator stations BL-2A and BL-11B with new focusing mirrors at the Photon Factory [J].
Kitajima, Y .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1996, 80 :405-408
[7]   Comparison of the absolute soft X-ray intensity between a cryogenic radiometer and an ion chamber [J].
Morishita, Y ;
Saito, N ;
Suzuki, IH .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2005, 144 :1071-1073
[8]   DESIGN AND PERFORMANCE OF A UHV COMPATIBLE SOFT-X-RAY DOUBLE CRYSTAL MONOCHROMATOR AT THE PHOTON FACTORY [J].
OHTA, T ;
STEFAN, PM ;
NOMURA, M ;
SEKIYAMA, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :373-376
[9]   Synchrotron-radiation-operated cryogenic electrical-substitution radiometer as the high-accuracy primary detector standard in the ultraviolet, vacuum-ultraviolet, and soft-x-ray spectral ranges [J].
Rabus, H ;
Persch, V ;
Ulm, G .
APPLIED OPTICS, 1997, 36 (22) :5421-5440
[10]   Absolute fluence rates of soft X-rays using a double ion chamber [J].
Saito, N ;
Suzuki, IH .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1999, 101 :33-37