Development of a compact supersonic jet/multiphoton ionization/time-of-flight mass spectrometer for the on-site analysis of dioxin, part II: Application to chlorobenzene and dibenzofuran

被引:22
作者
Matsumoto, J
Nakano, B
Imasaka, T [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Dept Appl Chem, Higashi Ku, Fukuoka 8128581, Japan
[2] Ulvac Kyushu Corp, Fukuoka 8191613, Japan
关键词
D O I
10.2116/analsci.19.383
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A compact supersonic jet/multiphoton ionization/mass spectrometer (SSJ/MPI/MS) equipped with a single pump system was developed for use in the analysis of dioxin. A mass spectrum and multiphoton ionization spectrum were obtained for chlorobenzene and dibenzofuran using an optical parametric oscillator (OPO) for excitation and subsequent ionization. The detection limit for chlorobenzene (S/N = 3) was 0.3 ppb, which corresponds to an absolute amount of 0.1 pg. The rotational temperature was 35 K. This slightly high temperature can be attributed to the long nozzle throat used in the instrument.
引用
收藏
页码:383 / 386
页数:4
相关论文
共 19 条
[1]   New quenching scheme for the generation of a nearly transform-limited picosecond pulse in a distributed feedback dye laser [J].
Deguchi, T ;
Takeyasu, N ;
Imasaka, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (05) :2203-2204
[2]   Measurement of the first-excited-singlet-state lifetime of chlorobenzenes by a pump-probe method using a narrow-band tunable picosecond laser [J].
Deguchi, T ;
Takeyasu, N ;
Imasaka, T .
APPLIED SPECTROSCOPY, 2002, 56 (09) :1241-1243
[3]   A capillary-based supersonic jet inlet system for resonance-enhanced laser ionization mass spectrometry: Principle and first on-line process analytical applications [J].
Hafner, K ;
Zimmermann, R ;
Rohwer, ER ;
Dorfner, R ;
Kettrup, A .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4171-4180
[4]   SUPERSONIC JETS, ROTATIONAL COOLING, AND ANALYTICAL-CHEMISTRY [J].
HAYES, JM ;
SMALL, GJ .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :A565-&
[5]   OPTICALLY SELECTIVE MOLECULAR MASS-SPECTROMETRY [J].
LUBMAN, DM .
ANALYTICAL CHEMISTRY, 1987, 59 (01) :A31-A40
[6]   Using Thermogravimetry for weight loss monitoring of permeation tubes used for generation of trace concentration gas standards [J].
Maria, PC ;
Gal, JF ;
Balza, M ;
Peré-Trepat, E ;
Tumbiolo, S ;
Couret, JM .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :305-307
[7]   Effect of laser pulse width on ionization efficiency in supersonic beam-multiphoton ionization mass spectrometry [J].
Matsumoto, J ;
Imasaka, T .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3763-3768
[8]   Use of ring-repeller, double-skimmer electrodes for efficient ion focusing in mass spectrometry [J].
Matsumoto, J ;
Saito, G ;
Imasaka, T .
ANALYTICAL SCIENCES, 2002, 18 (05) :567-570
[9]   Enhancement of the molecular ion peak from halogenated benzenes and phenols using femtosecond laser pulses in conjunction with supersonic beam multiphoton ionization mass spectrometry [J].
Matsumoto, J ;
Lin, CH ;
Imasaka, T .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4524-4529
[10]   A mobile mass spectrometer for comprehensive on-line analysis of trace and bulk components of complex gas mixtures:: Parallel application of the laser-based ionization methods VUV single-photon ionization, resonant multiphoton ionization, and laser-induced electron impact ionization [J].
Mühlberger, F ;
Zimmermann, R ;
Kettrup, A .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3590-3604