Immobilized particle arrays: Coalescence of planar- and suspension-array technologies

被引:27
作者
Stevens, PW
Wang, CHJ
Kelso, DM
机构
[1] Northwestern Univ, Robert R McCormick Sch Engn & Appl Sci, Dept Biomed Engn, Evanston, IL 60208 USA
[2] Spherotech Inc, Libertyville, IL 60048 USA
关键词
D O I
10.1021/ac020580d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Combining positive attributes of planar arrays and suspension arrays, immobilized particle arrays offer a new format in which immobilized submicrometer particles are arrayed on hydrogel-coated slides, providing 100+ assay replicates within each spot. Ibis research describes how to prepare immobilized protein arrays and how to assay the binding of labeled target molecules to the arrayed capture probes. The assay system exhibits an intrinsic dynamic range of two to three decades, with coefficients of variation from 5 to 10%. For antibody-antigen binding, target capture appears to be reaction rate limited. For labeled antibody binding to antigen on the immobilized particles, the detection limit is similar to0.5 ng/mL When antibodies on the immobilized particles exhibit multivalent binding of target molecules, the detection limit is similar to0.01 ng/mL. For protein arrays, potential advantages of this format are improved coating of the capture reagent, an increased number of options for protein presentation, reduced mass transport effects, and higher density multiplexing.
引用
收藏
页码:1141 / 1146
页数:6
相关论文
共 45 条
[1]   Gene expression analysis by massively parallel signature sequencing (MPSS) on microbead arrays [J].
Brenner, S ;
Johnson, M ;
Bridgham, J ;
Golda, G ;
Lloyd, DH ;
Johnson, D ;
Luo, SJ ;
McCurdy, S ;
Foy, M ;
Ewan, M ;
Roth, R ;
George, D ;
Eletr, S ;
Albrecht, G ;
Vermaas, E ;
Williams, SR ;
Moon, K ;
Burcham, T ;
Pallas, M ;
DuBridge, RB ;
Kirchner, J ;
Fearon, K ;
Mao, J ;
Corcoran, K .
NATURE BIOTECHNOLOGY, 2000, 18 (06) :630-634
[2]   Biomolecular recognition on well-characterized beads packed in microfluidic channels [J].
Buranda, T ;
Huang, JM ;
Perez-Luna, VH ;
Schreyer, B ;
Sklar, LA ;
Lopez, GP .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1149-+
[3]   THE ADSORPTIVE CHARACTERISTICS OF PROTEINS FOR POLYSTYRENE AND THEIR SIGNIFICANCE IN SOLID-PHASE IMMUNOASSAYS [J].
CANTARERO, LA ;
BUTLER, JE ;
OSBORNE, JW .
ANALYTICAL BIOCHEMISTRY, 1980, 105 (02) :375-382
[4]  
CUSSLER EL, 1984, DIFFUSION, P42
[5]   Robust and efficient synthetic method for forming DNA microarrays [J].
Dolan, PL ;
Wu, Y ;
Ista, LK ;
Metzenberg, RL ;
Nelson, MA ;
Lopez, GP .
NUCLEIC ACIDS RESEARCH, 2001, 29 (21) :107-107
[6]  
Eisen MB, 1999, METHOD ENZYMOL, V303, P179
[7]  
EKINS RP, 1991, CLIN CHEM, V37, P1955
[8]  
Feeney R, 2000, ELECTROANAL, V12, P677, DOI 10.1002/1521-4109(200005)12:9<677::AID-ELAN677>3.0.CO
[9]  
2-4
[10]   High-density fiber-optic DNA random microsphere array [J].
Ferguson, JA ;
Steemers, FJ ;
Walt, DR .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5618-5624