Direct detection and discrimination of double-stranded oligonucleotide corresponding to hepatitis C virus genotype 3a using an electrochemical DNA biosensor based on peptide nucleic acid and double-stranded DNA hybridization

被引:47
作者
Pournaghi-Azar, M. H. [1 ]
Ahour, F. [1 ]
Hejazi, M. S. [2 ,3 ,4 ]
机构
[1] Univ Tabriz, Electroanalyt Chem Lab, Fac Chem, Tabriz 5166614776, Iran
[2] Tabriz Univ Med Sci, Fac Pharm, Tabriz 51664, Iran
[3] Tabriz Univ Med Sci, Drug Appl Res Ctr, Tabriz 51664, Iran
[4] Tabriz Univ Med Sci, Pharmaceut Nanotechnol Res Ctr, Tabriz 51664, Iran
关键词
DNA biosensor; Hepatitis C; PNA probe; Triplex formation; Gold electrode; PENCIL GRAPHITE ELECTRODE; ION-CHANNEL SENSORS; HUMAN INTERLEUKINE-2 GENE; LABEL-FREE; VOLTAMMETRIC DETECTION; ARTIFICIAL RECEPTORS; POINT MUTATION; GOLD SURFACES; PNA; PROBE;
D O I
10.1007/s00216-010-3875-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Development of an electrochemical DNA biosensor for the direct detection and discrimination of double-stranded oligonucleotide ( dsDNA) corresponding to hepatitis C virus genotype 3a, without its denaturation, using a gold electrode is described. The electrochemical DNA sensor relies on the modification of the gold electrode with 6-mercapto-1-hexanol and a self-assembled monolayer of 14-mer peptide nucleic acid probe, related to the hepatitis C virus genotype 3a core/E1 region. The increase of differential pulse voltammetric responses of methylene blue, upon hybridization of the self-assembled probe with the target ds-DNA to form a triplex is the principle behind the detection and discrimination. Some hybridization experiments with non-complementary oligonucleotides were carried out to assess whether the developed DNA sensor responds selectively to the ds-DNA target. Diagnostic performance of the biosensor is described and the detection limit was found to be 1.8x10(-12) M in phosphate buffer solution, pH 7.0. The relative standard deviation of measurements of 100 pM of target ds-DNA performed with three independent probe-modified electrodes was 3.1%, indicating a remarkable reproducibility of the detection method.
引用
收藏
页码:3581 / 3587
页数:7
相关论文
共 41 条
[1]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[2]  
Aoki H, 2000, ELECTROANAL, V12, P1272, DOI 10.1002/1521-4109(200011)12:16<1272::AID-ELAN1272>3.0.CO
[3]  
2-F
[4]  
Aoki H, 2007, ANALYST, V132, P784, DOI 10.1039/b704214k
[5]   PNA/dsDNA complexes: Site specific binding and dsDNA biosensor applications [J].
Baker, Erin Shammel ;
Hong, Janice W. ;
Gaylord, Brent S. ;
Bazan, Guillermo C. ;
Bowers, Michael T. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (26) :8484-8492
[6]   Current strategies for electrochemical detection of DNA with solid electrodes [J].
de-los-Santos-Alvarez, P ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (01) :104-118
[7]   STABILITY OF PEPTIDE NUCLEIC-ACIDS IN HUMAN SERUM AND CELLULAR-EXTRACTS [J].
DEMIDOV, VV ;
POTAMAN, VN ;
FRANKKAMENETSKII, MD ;
EGHOLM, M ;
BUCHARD, O ;
SONNICHSEN, SH ;
NIELSEN, PE .
BIOCHEMICAL PHARMACOLOGY, 1994, 48 (06) :1310-1313
[8]   PNA HYBRIDIZES TO COMPLEMENTARY OLIGONUCLEOTIDES OBEYING THE WATSON-CRICK HYDROGEN-BONDING RULES [J].
EGHOLM, M ;
BUCHARDT, O ;
CHRISTENSEN, L ;
BEHRENS, C ;
FREIER, SM ;
DRIVER, DA ;
BERG, RH ;
KIM, SK ;
NORDEN, B ;
NIELSEN, PE .
NATURE, 1993, 365 (6446) :566-568
[9]   PEPTIDE NUCLEIC-ACIDS (PNA) - OLIGONUCLEOTIDE ANALOGS WITH AN ACHIRAL PEPTIDE BACKBONE [J].
EGHOLM, M ;
BUCHARDT, O ;
NIELSEN, PE ;
BERG, RH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (05) :1895-1897
[10]   Label-free detection of peptide nucleic acid-DNA hybridization using localized surface plasmon resonance based optical biosensor [J].
Endo, T ;
Kerman, K ;
Nagatani, N ;
Takamura, Y ;
Tamiya, E .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :6976-6984