Development of a three-dimensional finite element model for carpal load transmission in a static neutral posture

被引:76
作者
Carrigan, SD
Whiteside, RA
Pichora, DR
Small, CF
机构
[1] Queens Univ, Dept Engn Mech, Kingston, ON, Canada
[2] Kingston Gen Hosp, Kingston, ON K7L 2V7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
carpal; wrist; load transmission; three-dimensional; finite element;
D O I
10.1114/1.1574027
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
A three-dimensional developmental finite element model has been created to analyze load transmission pathways in the constrained carpus during static compressive loading. The bone geometry was extracted from an in vivo computed tomography scan using a combination of commercial and proprietary software. The complete geometry, including bone, cartilage, and ligament tissues, was compiled using a commercial finite element program. This model extends the state of biomechanical modeling by being the first to incorporate all eight carpal bones of the wrist and the related soft tissues in three dimensions. The model results indicate that cartilage material modulus and unconstrained carpal rotation have substantial impacts on the articular contact patterns and pressures. (C) 2003 Biomedical Engineering Society.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 19 条
[1]
Anderson D D, 1995, Semin Arthroplasty, V6, P30
[2]
Berger RA, 1997, HAND CLIN, V13, P63
[3]
Material properties of the trapezial and trapeziometacarpal ligaments [J].
Bettinger, PC ;
Smutz, P ;
Linscheid, RL ;
Cooney, WP ;
An, KN .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (06) :1085-1095
[4]
Contact analysis of biphasic transversely isotropic cartilage layers and correlations with tissue failure [J].
Donzelli, PS ;
Spilker, RL ;
Ateshian, GA ;
Mow, VC .
JOURNAL OF BIOMECHANICS, 1999, 32 (10) :1037-1047
[5]
Three-dimensional motion patterns of the carpel bones:: an in vivo study using three-dimensional computed tomography and clinical applications [J].
Feipel, V ;
Rooze, M .
SURGICAL AND RADIOLOGIC ANATOMY, 1999, 21 (02) :125-131
[6]
Biomechanical analysis of limited intercarpal fusion for the treatment of Kienbock's disease: A three-dimensional theoretical study [J].
Iwasaki, N ;
Genda, E ;
Barrance, PJ ;
Minami, A ;
Kaneda, K ;
Chao, EYS .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (02) :256-263
[7]
Ledoux P, 2001, Acta Orthop Belg, V67, P236
[8]
Lewis G, 1995, Semin Arthroplasty, V6, P20
[9]
Variability of a three-dimensional finite element model constructed using magnetic resonance images of a knee for joint contact stress analysis [J].
Li, G ;
Lopez, O ;
Rubash, H .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (04) :341-346
[10]
A validated three-dimensional computational model of a human knee joint [J].
Li, G ;
Gil, J ;
Kanamori, A ;
Woo, SLY .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (06) :657-662