Quantification of o,o′-dityrosine, o-nitrotyrosine, and o-tyrosine in cat urine samples by LC/electrospray ionization-MS/MS using isotope dilution

被引:46
作者
Marvin, LF
Delatour, T
Tavazzi, I
Fay, LB
Cupp, C
Guy, PA
机构
[1] Nestec Ltd, Nestle Res Ctr, CH-1000 Lausanne 26, Switzerland
[2] Nestle Purina Res, Prod Technol Ctr, St Joseph, MO 64503 USA
关键词
D O I
10.1021/ac020309w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantification of o-tyrosine, o-nitrotyrosine, and o,o'-dityrosine from cat urine samples was achieved by LC/electrospray ionization-MS/MS (LC/ESI-MS/MS) using an isotope dilution technique in multiple reaction monitoring mode before butylation of o,o'-dityrosine and after butylation of o-tyrosine and o-nitrotyrosine. This novel approach of amino acids butylation enhanced the MS response by a factor of 7-fold for o-tyrosine and 6-fold for o-nitrotyrosine and decreased the overall chemical background noise. Butylation of o,o'-dityrosine resulted in a lower MS response as a result of the formation of both mono- and doubly butylated species. The mean recovery for the oxidized amino acids was estimated at 73 +/- 2%. The limits of quantitation of NO2-Tyr butyl ester, o-Tyr butyl ester, and di-Tyr in cat urine samples were calculated at 14.5, 28.2 and 140.9 nM, respectively. The oxidized amino acids levels in cat urine extracts ranged from 157 to 250 ng/day for o-Tyr and from 3289 to 11803 ng/day for di-Tyr. NO2-Tyr was found in only two urine extracts at levels below 58 ng/day. A certain trend of correlation was observed between o,o'-dityrosine and o-tyrosine when comparing these values against their respective creatinine amounts. A comparison of the data gathered from the ThermoFinnigan TSQ 7000 and Micromass Q-TOF instruments revealed several advantages of using the Q-TOF regarding the exact mass measurement, a lower ion suppression effect and the possibility to perform analyses in full scan product ion mode. These results demonstrate that a Q-TOF instrument can be a good alternative to classical triple quadrupole for quantitative purposes on a relatively small linear dynamic range (4 orders of magnitude for the Q-TOF, as compared to 6 for the triple quadrupole).
引用
收藏
页码:261 / 267
页数:7
相关论文
共 26 条
[1]   LC-MS/MS detection of peroxynitrite-derived 3-nitrotyrosine in rat microvessels [J].
Althaus, JS ;
Schmidt, KR ;
Fountain, ST ;
Tseng, MT ;
Carroll, RT ;
Galatsis, P ;
Hall, ED .
FREE RADICAL BIOLOGY AND MEDICINE, 2000, 29 (11) :1085-1095
[2]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[3]   OXYGEN FREE-RADICALS AND HUMAN-DISEASES [J].
ARUOMA, OI ;
KAUR, H ;
HALLIWELL, B .
JOURNAL OF THE ROYAL SOCIETY OF HEALTH, 1991, 111 (05) :172-177
[4]  
BAYSE GS, 1972, BIOCHIM BIOPHYS ACTA, V284, P34
[5]   Protein oxidation in aging, disease, and oxidative stress [J].
Berlett, BS ;
Stadtman, ER .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (33) :20313-20316
[6]  
CHACE DH, 1995, CLIN CHEM, V41, P62
[7]  
Chace DH, 1997, CLIN CHEM, V43, P2106
[8]   ROBUST STATISTICS IN ANALYTICAL-CHEMISTRY [J].
DANZER, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :869-875
[9]  
DEIATOUR T, 2002, ANAL BIOCHEM, V302, P10
[10]   HYDROXYL RADICAL MEDIATED DAMAGE TO PROTEINS, WITH SPECIAL REFERENCE TO THE CRYSTALLINS [J].
GUPTASARMA, P ;
BALASUBRAMANIAN, D ;
MATSUGO, S ;
SAITO, I .
BIOCHEMISTRY, 1992, 31 (17) :4296-4303