Practical guidelines for optimal gamma probe detection of sentinel lymph nodes in breast cancer: Results of a multi-institutional study

被引:139
作者
Martin, RCG
Edwards, MJ
Wong, SL
Tuttle, TM
Carlson, DJ
Brown, CM
Noyes, RD
Glaser, RL
Vennekotter, DJ
Turk, PS
Tate, PS
Sardi, A
Cerrito, PB
McMasters, KM
机构
[1] Univ Louisville, James Graham Brown Canc Ctr, Dept Surg, Div Surg Oncol, Louisville, KY 40202 USA
[2] Univ Louisville, Dept Math, Louisville, KY 40202 USA
[3] Pk Nicollett Clin, Minneapolis, MN USA
[4] St Marys Med Ctr & Deaconess Hosp, Evansville, IN USA
[5] Norton Hosp, Louisville, KY USA
[6] LDS Hosp, Salt Lake City, UT USA
[7] Kettering Mem Hosp, Kettering, OH USA
[8] Presbyterian Hosp, Charlotte, NC USA
[9] Cent Baptist Hosp, Lexington, KY USA
[10] St Agnes Healthcare, Baltimore, MD USA
关键词
D O I
10.1067/msy.2000.108064
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction. Multiple radioactive lymph nodes are often removed during the course of sentinel lymph node (SLN) biopsy for breast cancer when both blue dye and radioactive colloid injection are used. Some of the less radioactive lymph nodes are second echelon nodes, not true SLNs. The purpose of this analysis was to determine whether harvesting these less radioactive nodes, in addition to the "hottest" SLNs, reduces the false-negative rate. Methods. Patients were enrolled in this multicenter (121 surgeons) prospective, institutional review board-approved study after informed consent was obtained. Patients with clinical stage T1-2, N0, MO invasive breast cancer were eligible. This analysis includes all patients who underwent axillary SLN biopsy with the use of an injection of both isosulfan blue dye and radioactive colloid. The protocol specified that all blue nodes and all nodes with 10% or more of the ex vivo count of the hottest node should be removed and designated SLNs. All patients underwent completion level I/II axillary dissection. Results. SLNs were identified in 672 of 758 patients (89%). Of the patients with SLNs identified, 403 patients (60%) had more than 1 SLN removed (mean, 1.96 SLN/patient) and 207 patients (31%) had nodal metastases. The use of filtered or unfiltered technetium sulfur colloid had no impact on the number of SLNs identified. Overall, 33% of histologically positive SLNs had no evidence of blue dye staining. Of those patients with multiple SLNs removed, histologically positive SLNs were found in 130 patients. In 25 of these 130 patients (11.5%), the hottest SLN was negative when a less radioactive node was positive for tumor if only the hottest node had been removed the false-negative rate would have been 13.0% versus 5.8% when all nodes with 10% or more of the ex vivo count of the hottest node were removed (P = .01). Conclusions. These data support the policy that all blue nodes and all nodes with 10% or more of the ex vivo count of the hottest SLN should be harvested for optimal nodal staging.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 17 条
[1]   Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[2]  
Cody HS, 1999, ONCOLOGY-NY, V13, P25
[3]  
Cox CE, 1998, ONCOLOGY-NY, V12, P1283
[4]  
EDWARDS MJ, 2000, CONSENSUS STATEMENT
[5]   Sentinel lymphadenectomy in breast cancer [J].
Giuliano, AE ;
Jones, RC ;
Brennan, M ;
Statman, R .
JOURNAL OF CLINICAL ONCOLOGY, 1997, 15 (06) :2345-2350
[6]  
Guenther JM, 1997, CANCER J SCI AM, V3, P336
[7]   Sentinel lymphatic mapping in breast cancer [J].
Hill, ADK ;
Mann, GB ;
Borgen, PI ;
Cody, HS .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1999, 188 (05) :545-549
[8]   The sentinel node in breast cancer - A multicenter validation study [J].
Krag, D ;
Weaver, D ;
Ashikaga, T ;
Moffat, F ;
Klimberg, VS ;
Shriver, C ;
Feldman, S ;
Kusminsky, R ;
Gadd, M ;
Kuhn, J ;
Harlow, S ;
Beitsch, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (14) :941-946
[9]   Sentinel lymph node biopsy in breast cancer: Unfiltered radioisotope is superior to filtered [J].
Linehan, DC ;
Hill, ADK ;
Tran, KN ;
Yeung, H ;
Yeh, SDJ ;
Borgen, PI ;
Cody, HS .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1999, 188 (04) :377-381
[10]   Carbon dye as an adjunct to isosulfan blue dye for sentinel lymph node dissection [J].
Lucci, A ;
Turner, RR ;
Morton, DL .
SURGERY, 1999, 126 (01) :48-53